2008

Table Of Contents
to query the table to find the correct mapping entry
for a given block name to swap.
If blank, the new block swaps in at the same scale as
the existing block it replaces. If this field is not blank,
Column D/ Scale Multiplier
the swapped block is scaled up or down per the
field's multiplier value.
If blank, the new block swaps in at the same XY co-
ordinate as the existing block it replaces. If not blank
Column E / X-Y Offset
and in the format of a coordinate pair, the swapped
block inserts offset from the original block's origin
by this XY amount.
Defines specific attribute Old=New mapping that is
not defined in sheet 1 or is to override what is found
Column F / Attribute name overrides
in sheet 1. Multiple entries in this field are supported
with this syntax: Old1=New1;Old2=New2.
Defines specific attribute values to insert into the
newly swapped attributes. Multiple entries in this
Column G / Attribute Value Overrides
field are supported with this syntax:
New1=val1;New2=val2. An entry of "New1=" blanks
out that attribute value.
The block replacement process generates a log file of the results. The log file
({projectname}_cnv.log) is created in the same folder as the .wdp project file.
The following conditions are reported:
Problem finding/opening mapping spreadsheet
Problem inserting WD_M block (if not already present)
Legacy block name not mapped to an AutoCAD Electrical block
AutoCAD Electrical block not found in library search path
Problem inserting AutoCAD Electrical block
Legacy attribute name not mapped
Overview of block/attribute mapping | 1153