None (text only) - enter the gap value (the amount of space between
the end of the leader line and the text).
Specifies the text size for the marker.Text
Specifies the arrowhead and size. Choose the type of arrowhead for
the leader from the list and enter the arrowhead size in the box. These
values correspond to AutoCAD leader/dimension system variables.
Arrow
Resequence panel item numbers
This tool assigns or resequences item number assignments on a drawing or
project. This extracts all panel components and nameplates and resequences
their item numbers starting at the value you provide. Resequencing is based
on the main MFG/CAT/ASSYCODE value combination. Additional
multi-catalog numbers on a specific component are ignored. Only the main
part number combination is used to group similar components together under
a common item number.
Access:
Click the arrow on the Miscellaneous Panel Tools tool to access the Resequence
Item Numbers tool.
From the Panel Layout menu, select Miscellaneous Panel Tools Resequence
Item Numbers.
Select the beginning item number to use. This processes the drawing or project
drawing set and assigns incrementing item numbers for each new part number.
Any old item number assignments are overwritten with new ones, existing
balloons are updated, and repeated part numbers are assigned the same item
number, even when running project-wide.
Specifies the beginning number to use. Add leading zeros
if desired (ex: "001" instead of "1") to enable better report
sorting on item number.
Start
Specifies to process the data for the active drawing or the
entire project. If you select Project, you can select which
Drawings to Process
drawings to process from within the project. If you select
Active Drawing, other drawings are not checked for existing
item number assignments.
1090 | Chapter 15 Panel Layout