Adds any terminal description value as a suffix.Add terminal description to tag
Adds any installation value as a prefix.Include installation prefix to IEC tag
format
View/Test
Allows a preview or test of the report.
Suppress any duplicated annotation on each terminal
Indicates to hide duplicated annotations so that they do not show on the
report.
If wire numbering converts to MText
The default MText insertion point is the same as the footprint block's insertion
point. The default text size either matches that of existing wire number
attributes found on the footprint symbol or, if none present, the MText size
is forced to match the current value of the AutoCAD system variable
"TEXTSIZE".
If you want to predefine the MText insertion point, text size, and text style
on footprint blocks, you can do this by inserting an invisible attribute "WXREF"
on your footprint block library symbol. Open up each footprint symbol in
AutoCAD and insert a blank attribute definition "WXREF". Put its origin at
the point where you want AutoCAD Electrical to insert the block's MText wire
connection information. Mark this attribute definition invisible and set its
text size and style to the desired MText size and style.
Use the footprint lookup file
A key part of the AutoCAD Electrical design workflow is to first create the
schematic ladder controls diagrams and then use this information to help
automate the creation of the related physical panel layouts. The former shows
interconnected generic schematic symbols of the components and the latter
shows the related footprint representation of each component. These footprint
Lookup Files | 1081