There are two format edit boxes on the dialog. The "Full" format will be used
if AutoCAD Electrical does not find the target attributes and inserts MTEXT.
The "Partial" format is used if AutoCAD Electrical finds the target attributes
(described later). Each format uses parameters that are then replaced with the
specific wire information. AutoCAD Electrical provides some pre-defined
formats for you to select from the list box at the right. Or you can enter your
own format using replaceable parameters (page 126).
Parameters must be separated by non-blank delimiters for AutoCAD Electrical
to be able to re-extract wiring diagram information into reports. For example,
"%T=%W %1 %G" is not acceptable because there is only a space between the
%W and %1 and %G parameters. Acceptable formats include "%T=%W (%1)
%G" or "%T=%W / %1 (%G)" or "%T=%W (%1) %G".
NOTE Commas cannot be used in the format. They signal multiple wire connection
annotations onto a single wire connection attribute.
Additional options for the "To" component tag
There are additional options that can be included in the text.
Adds the terminal text as a suffix.Add terminal pin as a suffix to tag
Adds any terminal description value as a suffix.Add terminal description to tag
Adds any installation value as a prefix.Include installation prefix to IEC tag
format
View/Test
Allows a preview or test of the report.
Suppress any duplicated annotation on each terminal
Indicates to hide duplicated annotations so that they do not show on the
report.
1076 | Chapter 15 Panel Layout