2008

Table Of Contents
Optional item number assignmentITEM27
(blank)28
Panel terminals spreadsheet data format
The spreadsheet data for panel terminals must be in this order and have 30
columns of data and be saved in a "CSV comma delimited" text format. Most
of the fields can be left blank:
Terminal strip tag id (ex: "TB1")TAGSTRIP1
Optional installation codeINST2
Optional location codeLOC3
Optional mount codeMOUNT4
Optional group codeGROUPWIDTH5
Manufacturer codeMFG6
Catalog numberCAT7
Optional catalog assembly codeASM8
Optional count valueCNT9
Optional unit of measureUM10
Optional description textDESC1-DESC311-13
Optional schematic block name (blank)BLOCK14
Optional rating valuesRATING1-1215-26
Optional item number assignmentITEM27
1068 | Chapter 15 Panel Layout