2008

Table Of Contents
Descriptions
Specifies the optional description attribute text to assign to the terminal block
(up to 3 lines of text can be specified). Click Browse to search for all terminal
descriptions in the project or active drawing. Select the description you want
to copy to the edited terminal block by selecting it in the list and clicking OK.
Ratings
Specifies values for each ratings attribute. You can enter up to 12 ratings
attributes on a terminal. Select Show All Ratings to display a list of default
values.
NOTE If this button is unavailable, the terminal you are editing does not carry
any rating attributes.
Mount or Group
Changes the mount and group codes. You can search the current drawing or
entire project for the codes. A quick read of all the current or selected drawing
files is done and a list of codes used so far is returned. Select from the list to
automatically update the component with the codes.
Show/Edit Miscellaneous
View or edit any attributes that are not predefined AutoCAD Electrical
attributes.
External List
Assigns information from an external list to specified data in the Panel Layout
- Terminal Insert/Edit dialog box. Any existing information from the dialog
box appear in the edit box. To define the information from the selected file,
highlight the desired information in the Choices list and select the appropriate
button next to the desired edit box.
Schematic components list panel layout insert
This report provides error checking between the schematics and the panel
layout drawings. The program looks at the selected components, both
schematic and panel, to find a match in the project. For each schematic
component selected, the routine tries to find a matching panel component
based on tag, location, and installation information. If a match is found, then
it further compares catalog information looking for any discrepancies. The
1044 | Chapter 15 Panel Layout