2008

Table Of Contents
Minimum attribute/Xdata requirements
Below are the minimum requirements for AutoCAD Electrical to recognize a
block as a panel footprint or nameplate.
Component footprint - block must carry a minimum of one of the following:
VIA_WD_FPXdata name
FP (blank value)Attribute
P_TAG1 (and no attribute NP present)Attribute
Terminal footprint - block must carry a minimum of one of the following:
VIA_WD_FPTXdata name
FPT (blank value)Attribute
Panel nameplate - block must carry a minimum of one of the following:
VIA_WD_NPXdata name
NP (blank value)Attribute
Select Xdata to change to a block attribute
This tool converts any piece of non-visible extended entity data (Xdata) into
a visible attribute tied directly to the footprint block.
Access:
Click the arrow on the Edit Footprint tool to access the Make Xdata Visible tool.
Select a footprint.
From the Panel Layout menu, select Make Xdata Visible. Select a footprint.
After you click Insert, the dialog box disappears. Click on the location for the
attribute. The attribute inserts, is linked to the footprint block, and the dialog
1030 | Chapter 15 Panel Layout