Automatic wire numbering:
1 Click the Insert Wire Numbers tool.
2 In the Wire Tagging dialog box, select Insert as Fixed if it is
not already selected.
3 Click Project-wide, Drawing-wide, or Pick Individual Wires
depending on which method you want to use to update your
wire numbers.
Manually inserting wire numbers:
1 Click the Edit Wire Number tool.
2 Click a wire that does not currently have a wire number as-
signed to it.
3 In the Insert wire number dialog box, select Make it Fixed to
force the wire number to a fixed state.
4 Click OK.
Inserting wire numbers using project-wide utilities:
1 Click the arrow on the Projects New/Existing tool to access
the Project-Wide Utilities tool.
2 Click the Project-Wide Utilities tool.
3 In the Project-Wide Utilities dialog box, select Set all wire
numbers to fixed.
4 Click OK. All wire numbers in the project are now flagged as
fixed.
Autodesk Inventor Professional export
Extracts wire list information into an XML export file to be used exclusively
with Autodesk Inventor Professional Cable and Harness.
1018 | Chapter 14 Reports