Attaching Destination Signal Arrows | 55
4 In the Signal - Source Code dialog box, specify:
Code: 24 VDC NEUTRAL
Click OK.
5 In the Source/Destination Signal Arrows dialog box, click No.
NOTE Click No to insert the signal arrows on the next drawing. Click OK to
insert the signal arrows on the current drawing.
6 Click the Next Project Drawing tool to access demo04.dwg.
7 Click the drop-down arrow on the Source Destination Signals tool to access
the Destination Signal Arrow tool.
Menu Wires Signal References Destination Signal Arrow
8 Respond to the prompt as follows:
Select wire end for Destination:
Select the top of the neutral wire at line reference 402 (4)
4