2005

46 | Chapter 4 PLC
To insert terminals
1 Click the Multiple Insert Component tool.
Menu Components Multiple Insert Multiple Insert (Icon Menu)
2 In the Insert Component: JIC Schematic Symbols dialog box, click the
Terminals/Connectors button.
3 In the JIC: Terminals and Connectors dialog box, click the Round with
Terminal Number button.
4 Respond to the prompts as follows:
Component Fence, From Point: Select above wire at line reference 1001 (1)
Component Fence, From Point: to: Select below wire at line reference 1016 (2),
left click to end command, and then right-click to add terminal
5 In the Keep dialog box, select Keep this one, Show edit dialog after each, and
then click OK.
1
2