2008

In the Edit Property Set Data dialog, click OK.
4 Verify that the door tags are numbered sequentially. If they are not, use the Renumber Data Tool on the
Getting_Started tool palette to renumber the tags:
Click the Renumber Data Tool.
In the Data Renumber dialog, for Property Set, verify that DoorObjects is selected.
For Property, verify that Number is selected.
For Start Number and Increment, verify a value of 1.
Click OK, select the curtain wall entry door and the other doors on the plan, and press ENTER.
5 Create the door schedule:
On the Getting_Started tool palette, click the Door Schedule tool.
On the Properties palette, under Selection, for Scan xrefs, verify that Yes is selected.
On the command line, enter all, and press ENTER twice.
Specify a point on the left side of the floor plan view to place the upper-left corner of the schedule.
Press ENTER to place the schedule at the current drawing scale.
Zoom to a line on the schedule, and view the door information.
6 Tag the windows on the floor plan view to include them in a separate window schedule:
On the Getting_Started tool palette, click Window Tag.
Creating Schedules | 25