Tolerance Sets the maximum angular or positional deviation for a track.
Values are in units of translation for position tracks, and in degrees for rotation
tracks.
Minimum Key Spacing Sets the minimum number of frames between keys.
Tolerance is computed first, then Minimum Key Spacing computes further
key reduction.
A Minimum Key Spacing value of 10 for the head track ensures that no two
keys are closer than 10 frames for this track.
Filter Turn off to prevent filtering of the motion capture data into a track.
When this is off, there is no key reduction for the track.
Set All Forces all tracks to the values set in these fields.