Owner manual
9
4.3. Command Set
4.3.1. Command List for Local Device
Item Syntax Description Remarks
1. Connecting
address
AAddr<Enter> Set a remote device
address for a wireless
connection.
A local and remote
BD_ADDR always need to
be difference.
2. Baud rate BBaud Rate Change the baud rate Baud Rate - 0: 1200, 1:
2400, 2: 4800, 3: 9600, 4:
19200, 5: 38400, 6: 57600,
7: 115200
3. COM port CCOM Port
This is only valid in connection
mode 2.
4. PIN code EPIN<Enter>
Authentication Off: Type <Enter>
Authentication On: Type up to 11
characters
Paired adapters should
have a same PIN code.
5. Flow control FFlow Control
Set the Flow control.
0: None, 1: Hardware, 2:
DTR/DSR, 3: Hardware &
DTR/DSR
6. Connection
mode
Mmode Set a connection mode 0: 1:1 Mode, 1: WAIT Mode,
2: REGISTER and
CONNECT Mode
7. Friendly name Nname<Enter> Set a friendly name up to 11
characters.
8. Command for
the remote
O Enter configuration mode
for the remote.
9. Parity Bit Pparity Set the parity bit. 0: None, 1: Odd 2: Even
10. Stop Bit Sstop Set the stop bit. 0: 1 Stop, 1: 2 Stop
11. View V Display configuration
information
12. Exit X Apply changes.
13. Usage ? Print the usage.
Waning!
If you push the RST button, the COM port of HPS-120 will be stored the factory setting.