TROUBLESHOOTING
Before calling the authorised Service
Department, please check whether:
1. The instructions in the section ‘Using the
refrigerator’ have been followed.
2. The refrigerator is not tilted excessively.
3. It is possible to operate the refrigerator
with an available power source
POSSIBLE CAUSE ACTION YOU CAN TAKE
Failure : The refrigerator does not work in gas operation mode
Gasbottleempty.
Is the supply cut-out device open?
Air in the gas pipe?
Change gas bottle.
Open the cut-out device.
Switch device off and on again 3-4 times to
remove air from the gas pipe.
Failure : The refrigerator does not work on 12V
On-board fuse defective.
On-board battery discharged.
Engine not running.
Fit new fuse.
Check battery, charge it.
Start engine.
Failure : The refrigerator does not work on 230V
On-board fuse defective.
Noconnectiontosupplyvoltage.
AES: gas operation despite connection to the
supply voltage?
Fit new fuse.
Establish power connection.
Appliance switches to gas operation due
to insufficient supply voltage (automatically
switchesbackto230Voperation)
Failure : The refrigerator does not cool sufficiently
Inadequate ventilation to the unit.
The thermostat setting is too low.
There is too much ice on the condenser.
Too much warm food put inside.
Appliance running for a short time.
Check that the ventilation grilles are
not covered.
Turn the thermostat to a higher setting.
Check that the refrigerator door seals
when shut.
Let food cool down first.
Wait several hours, check again.
Note:TheSevenSeriesrefrigeratorrequires
a constant 12 volt supply for the fridge to
operate on gas. Disconnecting the leisure
battery will switch off the gas operation of
the fridge.
Switching off gas operation
If the refrigerator is to be taken out of service
for an extended period of time, the on-board
shut-off valve and the cylinder valve must
be closed.
WINTER OPERATION
1. Check that the ventilation grills and the
extractor have not been blocked by snow,
leaves or similar.
2. When the ambient temperature falls below
+8°C, the optional winter covers should
be fitted. This protects the unit from
excessively cold air.
Lower ventilation grille (L200)
Upper ventilation grille with flue
vent ( L100)
3. Affix the cover and fasten it.
Tip: It is also recommended that the winter
covers should be used when the vehicle is
taken out of service for an extended period
of time.
INTERIOR LIGHT
Changing the light bulbs
1. Remove cover.
2. Detach defective light bulb.
3. Fit new light bulb
4. Clip the cover back in place.
Note: For 12V DC : 1 light bulb 12V, 2W
Please contact Dometic Service Centres for