Specifications

equipment details
134
equipment details
135
AUTOMATIC ENERGY SELECTION (ONLY
WITH RM 7XX5 L)
‘AUTO’ operation
RM7XX5 L - models are equipped with an
‘AUTO’ MATIC function.
1. Set energy selection switch (A) to position
‘AUTO’. The LED ‘AUTO’ illuminates.
Note: Manual operation is possible at
any time.
Explanations
Upon switching on, the electronics
automatically select one of the three possible
energytypes:230V-12V–liquidgas.The
control electronics automatically ensure that
the refrigerator is supplied with the optimum
source of energy in each respective case.
Priority 1. Solar(12VDC)
2. 230VAC
3. 12VDC
4. Liquid gas
The selected energy is displayed by the
correspondingLED(i.e.230V).
230V - operation
If sufficient supply voltage is available (more
than200V),thispowersourceisselectedas
the first option ( no solar-system installed).
12V - operation
12Voperationshouldonlybeselected
while the vehicle motor is running or there
is sufficient voltage available from the sola
system. This can be detected from the D+
connection of the alternator to the electronics,
or from the respective signal on the solar
charge regulator.
Gas operation
Gasoperationisselectedinthe
following circumstances:
•Nosupplyvoltageavailable.
•Thevehicleengineisnotrunning.
•Supplyvoltagelessthan200V
Refuelling Stop
In order to prevent unintended switching to
gas operation during refuelling, the electronic
system starts gas operation of the refrigerator,
after the motor has been turned off for 15
mins. During this time the appliance is in
stand-by operation mode and only the ‘AUTO’
LED lights up
The use of naked flames is prohibited
in petrol station environments. If the
refuelling stop lasts longer than 15 mins
the refrigerator should be switched off at
the main switch (A), or switched over to
another energy type.
Gas faults at ‘AUTO’ mode
If gas faults occur the operating LED ‘C’
ashesyellow.
A
C
Remedies:
Set the energy selector switch (A) to
position ‘OFF’.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
1. Setenergyselectorswitch(A)to230V.
2. Operatingdisplay‘C’,230Vlights‘green’.
Appliance is in function.
B
3. Use rotary switch (B) to regulate the
temperature in the main refrigerator
compartment.
Note:Iftheoperatingdisplayfailstolightup
(it lights up ‘red’ at AES models) the device is
not in operation. (For troubleshooting see page
105)
Gas operation
• Therefrigeratorshouldonlybeoperated
using liquid gas (propane, butane). Do not
use town gas or natural gas.
• Iftherefrigeratorisoperatedduringtravel
using gas, the precautions stipulated by
the legislation in the respective country
must be taken (in conformity with the
EuropeanstandardEN732).
• Operatingtherefrigeratorwithgasisnot
permitted during travel in France and
Australia.
• Asabasicrule,operationusinggasis
prohibited in petrol stations.
1. Open the valve of the gas cylinder
2. Open the shut-off valve to the gas supply.
A
C
3. Set energy selector switch (A) to gas
4. Set rotary switch (B) to ‘MAX’ position.
The ignition process is activated automatically,
accompanied by a ticking sound approx. 30 sec.
Upon successful ignition, the display LED (C)
‘Gas’lightsyellow.Therefrigeratorisinfunction.
Use rotary switch (B) to regulate the temperature
in the main refrigerator compartment.
GAS FAULTS
In the event of a gas fault (e.g. gas cylinder
empty),theoperatingdisplay(C)ashesyellow.
A
C
Remedies:
Set the energy selector switch (A) to
position ‘OFF’.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to ‘on’
The re-ignition starts again.
If after about 30 seconds the operating display
(C)startsashingredagain,thegasfaulthas
not been cleared (e.g. air in the gas pipe).
5. Brieyswitchtherefrigeratoroffandthen
on again using main switch (A).
To remove air from the gas pipes, repeat
this procedure 3-4 times.
If these actions do not help, please call an