Specifications
equipment details
92
equipment details
93
Water pressure:
max. 2.8 bar
Rated thermal output
C 4002: 2000/4000 W
C 6002: 2000/4000/6000 W
Gas consumption
C 4002: 170 – 320 g/h
C 6002: 170 – 480 g/h
Air delivery volume (freeblowing without
hot-air pipe)
C 4002: with 3 hot-air outlets max. 249 m3/h
with 4 hot-air outlets max. 287 m3/h
C 6002: with 4 hot-air outlets max. 287 m3/h
Current input at 12 V
Heater + water heater C 4002: 0.2 – 5.6 A
(average power consumption 1.3 A)
C 6002: 0.2 – 5.6 A (average power
consumption 1.4 A)|
Heating up of water heater:
0.4 A
Stand-by:
0.001 A
Current input of electrical safety/drain
valve at 12 V:
0.035 A
Weight:
17.6 kg (without water contents)
Declaration of conformity:
TheTrumaticChasbeentestedbytheDVGW
and complies with the gas equipment directive
(90/396/EEC) and the other applicable EC
directives.ThefollowingCEProductIdent.No.
is available for EU countries
C 4002: CE-0085AS0121
C 6002: CE-0085AS0122.
The heater complies with heater directive
2001/56/EC and supplements 2004/78/EC
and 2006/119/EC and bears the type
approval number
C 4002: e1 00 0147
C 6002: e1 00 0146.
The heater complies with vehicle engine
interference suppression directive 72/245/EEC
with supplements 2004/104/EC and 2005/83/
EC, and bears type approval number:
e1 03 2499.
The heater complies with EMC directive
89/336/EEC and low voltage directive
73/23/EEC.
The right to effect technical modifications is
reserved!
truma trouble shooting list
FAULT CAUSE RECTIFICATION
Gas operation
Nocontrollamplightsup
when the system is switched
on (winter and summer
operation).
Device fuse or vehicle
fuse defective.
Open window above cowl
(window switch).
Chargebatteryvoltage(12V).
Check all electrical plug
connections/fuses.
Close window.
The green indicator lamp
comes on when the
equipment is switched on
(using the
ZUC timer), but the heater is
not operating.
Open window above cowl
(window switch).
Close window.
Theredmonitorlampashes
after the heating system has
been switched on.
Warning! Battery voltage is
toolow(<10.5V).
Charge battery!
About 30 seconds after the
heating has been switched on,
the red monitor lamp lights up
and remains steady.
Gascylinderorquick-closure
valve in the gas line is closed.
Air feed interrupted.
Check gas feed.
Check cowl for
possible coverage.
If being used on boats, open
the deck cowl.
Heating switches to Fault
mode after an extended
period of operation.
Hot-air outlets blocked.
Gaspressureregulatoricedup.
Butane content in the gas
cylinder too high.
Check individual
outlet apertures.
Use de-icing system
controller (EisEx).
Use propane (at temperatures
below 10°C in particular,
butane is unsuitable for
heating purposes).
230 V electrical operation
Nocontrollamplightsupwhen
the system is switched on.
Nosupplyvoltage. Check230Vsupplyvoltage
and fuses.