Specifications

equipment details
86
equipment details
87
FUNCTION DESCRIPTION
The Trumatic C is a hot-air liquid-gas heating
system with integrated hot water boiler
(12 litres content). The burner operates
fan-supported, which ensures trouble- free
function even when on the move.
In winter operation (heating and hot water)
the device automatically selects the output
level required, depending on the temperature
difference between the room temperature
which has been set and the temperature at
the particular time. The Type C 6002 operates
at three output stages (2000, 4000, and
6000 W), and the Type C 4002 at two stages
(2000 and 4000 W). With the boiler filled,
the water will be automatically heated at the
same time. The water temperature depends on
the selected operating mode and the heating
power that is being emitted (with or without
water temperature monitoring or with drained
water system).
Heating operation is basically possible
without restriction with or without
water content.
In summer operation (hot water only), the
heating of the water content takes place
at the lowest burner stage. Once the water
temperature has been reached, the burner
switches off and the yellow monitor lamp
goes out.
Trumatic C EL units have an additional 230
Velectricheatingcapabilityavailableasan
option (450 W/2 A) for hot water.
IMPORTANT OPERATING NOTES
1. If the cowl has been placed near or directly
beneath an opening window, the device
trumatic c 4002
must be equipped with an automatic shut-
off device in order to prevent operation
with the window open.
2. The integrity and tight fit of the exhaust
gas double duct must be checked regularly,
particularly at the end of long trips. Also
check the mounting of the appliance and
the cowl.
3. Following a blow-back (misfire) always
have the exhaust gas system checked by
an expert!
4. Always keep the cowl for the exhaust
duct and combustion air intake free of
contamination (slush, ice, leaves etc.).
5. The installed temperature limiter shuts off
the gas supply if the appliance becomes
too hot. Therefore do not shut the warm
air outlets and the opening for the
returning circulating air.
6. Directive 2004/78/EC stipulates that a
safety shutoff device is required if motor
homes are being heated while driving. The
safety shut-off device is also recommended
for safety reasons if caravans are being
heated while driving.
The Truma SecuMotion gas pressure
regulator meets this requirement. If no
Truma SecuMotion gas pressure regulator
is installed, the gas cylinder must be closed
whilst driving and information signs must
be attached to the cylinder cabinet and in
the vicinity of the control panel.
7. Always use original Truma parts for
maintenance and repair work!
OPERATING INSTRUCTIONS
Always observe the operating instructions
and Important operating notes prior to
starting! The vehicle owner is responsible
for the correct operation of the appliance.
The installer or vehicle owner must apply the
yellow sticker with the warning information,
which is enclosed with the appliance, to a
place in the vehicle where it is clearly visible
to all users (e.g. on the wardrobe door)! Ask
Truma to send you stickers, if necessary.
Before using for the first time, it is
essential to flush the entire water supply
through with clean warm water. If the
heater is not being used, always drain the
water contents if there is a risk of frost.
There shall be no claims under guarantee
for damage caused by frost! Also drain the
water prior to repair or maintenance work
on the vehicle (in the workshop!) as the
electrical safety/drain valve opens when
the appliance is switched dead.
ELECTRICAL SAFETY/DRAIN VALVE
m = Control knob ‘closed’
n = Control knob ‘drain’
The safety/drain valve is held closed by an
electrical coil. To save battery power, we
recommend to open the valve if the vehicle
is not in use for a prolonged period!
If the temperature at the safety/drain valve
is less than 4°C, the water contents may
discharge on its own accord if the appliance is
not in operation (also if there is a failure)! To
avoid water loss, switch the device on (summer
or winter operation) and close the safety/drain
valve at the actuating button by raising it up
(position m).
Without heater operation, the safety/drain
valve can only be closed again at temperatures
above 8°C!
The draining socket of the electrical safety/drain
valve must always be kept clear (free from slush,
ice, leaves etc.)! There shall be no claims under
guarantee for damage caused by frost!
1 Cold water connection
2 Hot water connection
3 Gas connection
4 Hot air outlets
5 Circulating air return line
6 Waste gas discharge
7 Combustion air infeed
8 Electronic control unit
9 Cover for connection cable
10 Water container (12 litres)
11 Igniter
12 Burner
13 Heat exchanger
14 Overheating
protector
15 Temperature sensor
16 230 V heating collar for hot
water (Trumatic C EL only)
17 Control panels
18 Room temperature sensor