Specifications

electrical systems
68
electrical systems
69
SOUND SCREEN
TheSOUNDLEVELSCREENletsyouadjust
the volume of the Display (this will adjust the
Alarm and level sensing volume as well). As
the+or–symbolispressedsotheBarGraph
willmoveupanddownandtheVolumewill
increase or decrease accordingly enabling the
display to be muted.
TheScreenwillautomaticallyreturntotheON
SCREENafter2Minutesapproxoryoucan
returntotheSYSTEMSSCREENbypressingthe
RETURNSymbolontheScreen.
KEY FOB SCREEN & KEY FOB
TheKEYFOBSCREENallowsextraRemoteKey
Fobs to be coded to the Display. Press the Key
Fob Symbol on the Systems Screen which will
display the above for 10 seconds and the unit
will beep, during this time either button on the
Key Fob has to be pressed so that the Display
can recognise the Code and Store it into the
Display. After 10 seconds approx the Display
willreturntotheSYSTEMSSCREEN.
The Remote Key Fob has two Symbols and Ο.
Pressing the will switch on the Awning
LightanddisplayAWNintheTopLeftof
the On Screen.
Pressing the Ο will switch on the Entry Light.
If the range of the Key Fob reduces then the
battery may need replacing simply remove
the two screws from the Key Fob and replace
the battery.
WASTE ALARM SCREEN
When the Waste Water Tank is full then the
WASTEALARMSCREENwillbedisplayedand
the Display will beep 10 times, to clear this
fault the Waste Water Tank must be emptied
or the Screen pressed. If the Screen is pressed
but the Tank is not emptied then the Alarm
Screen fault will be shown again along with
the 10 beeps after 10 minutes approx.
This will continue until the Tank is emptied. If
the screen is not pressed then it will continue
to display the above and the 10 beeps will be
emitted every 2minutes approx. The Alarm
Sound can be turned off if required by pressing
theALARMSOUNDONSymbolthiswill
changetoALARMSOUNDOFFthisdoesnot
affect the Alarm screen itself as it will only turn
off the Audible side of the Alarm. If the Display
isturnedtotheOFFandthenONagainitwill
Default back to Alarm Sound On.
NOTETHEDISPLAYWILLAUTOMATICALLY
TURNOFFTHESOUNDONTHEWASTEALARM
BETWEENTHEHOURSOF8pmto8am.
WATER ALARM SCREEN
When the Fresh Water Tank is low then
theFRESHWATERALARMSCREENwillbe
displayed and the Display will beep 10 times,
to clear this fault the Fresh Water Tank must
be filled or the Screen pressed. If the Screen
is pressed but the Tank is not filled then the
Alarm Screen fault will be shown again along
with the 10 beeps after 10 minutes approx.
This will continue until the Tank is filled.
If the screen is not pressed then it will continue
to display the above and the 10 beeps will be
emitted every 2minutes approx. The Alarm
Sound can be turned off if required by pressing
theALARMSOUNDONSymbolthiswill
changetoALARMSOUNDOFFthisdoesnot
affect the Alarm screen itself as it will only turn
off the Audible side of the Alarm. If the Display
isturnedtotheOFFandthenONagainitwill
Default back to Alarm Sound On.
NOTETHEDISPLAYWILLAUTOMATICALLY
TURNOFFTHESOUNDONTHEWATERALARM
BETWEENTHEHOURSOF8pmto8am.
FUSE BLOWN ALARM SCREEN
The Display will monitor the Fuses on the PDU
Unit From 1 – 12 if any of the Fuses blow then
theFUSEBLOWNALARMSCREENwillbe
displayed and the Display will beep 10 times, to
clear this fault then the corresponding Fuse on
the 12v Distribution Unit must be replaced with
a Fuse of the same rating or the Screen pressed.
If the Screen is pressed but the Fuse is not
replaced then the Alarm Screen fault will be
shown again along with the 10 beeps after 10
minutes approx. This will continue until the Fuse
is replaced. If the screen is not pressed then it
will continue to display the above and the 10
beeps will be emitted every 2minutes approx.
If the fuse continues to blow then please
consult autocruise. Do not replace with a higher
rated fuse than is recommended on the 12v
distribution unit.
BATTERY WARNING ALARM
IftheHabitationBatteryVoltageistaken
below 10 volts then the above alarm will be
displayed. The Display will beep 10 times, to
clear this fault then the BATTERY MUST BE
CHARGEDortheScreenpressed.IftheScreen
is pressed but the battery is not charged will be
shown again along with the 10 beeps after 10
minutes approx.
This will continue until the battery is charged.
If the screen is not pressed then it will continue
to display the above and the 10 beeps will be
emitted every 2minutes approx.
NOTE:Itisstronglyrecommendedthatthe
batteries are charged if the screen displays
this by either the onboard mains charger or by
startingandrunningtheEngineoftheVehicle.
If this is not done then when the battery voltage
drops below 9volts then the system will shut
down so as not to drain the battery completely
at,whenthishappensthedisplaywillshow
SYSTEMSHUTDOWNHABITATIONBATTERY
LOW. To get the System working again the
Habitation Battery will have to be Charged.