Specifications

46
47
power consumption
230V MAINS ELECTRICAL EQUIPMENT
POWER CONSUMPTION
Please note:
Itispossiblethatthe230Vmainselectrical
equipment may not all operate simultaneously.
A typical UK motorhome site mains hook up
point provides a maximum output of 10 amps
and on some continental sites the available
output may be as low as 5 amps.
If your loading exceeds the site supply it may
trip the site circuit breaker. Please check the
available mains output with your site operator.
APPLIANCE 230V 12V LP GAS
Watts Amperes Watts Amperes grams/hour
Dometic Fridge 135w 0.6a Only when driving 11g/h
Ultraheat 500w
1000w
2000w
2.2a
4.3a
8.5a
12w
12w
12w
1.0a
1.0a
1.0a
N/A
N/A
N/A
S3002 Space Heater N/A N/A 12w 1.0a 30-280g/h
Ultrastore Water Heater 850w 3.7a N/A N/A 120g/h
Combi 4 2000w 8.5a 67w max 5.6a 160-320g/h
C4002EL 2000w 8.5a 67w max 5.6a 170-300g/h
Alde N/A N/A 6.0w 0.5a 245-405g/h
Alde 50Ow
1000w
2000w
2.2a
4.5a
8.5a
3.6w
3.6w
3.6w
0.3a
0.3a
0.3a
N/A
N/A
N/A
Caprice Cooker Hotplate
CapriceGrill
Caprice Oven
1N/A
2N/A
3N/A
4 800w
N/A
N/A
N/A
N/A
N/A
3.5a
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
112g/h
112g/h
172g/h
N/A
116g/h
116g/h
Triplex Cooker Hotplate
TriplexGrill
Triplex Oven
1N/A
2N/A
3N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
112g/h
112g/h
180g/h
115g/h
112g/h
SMEVhotplate N/A N/A N/A N/A 196-320g/h
Waeco Fridge 25w 0.108a 24w 2a N/A
Battery Charger 25A 500w 3.6a max N/A N/A N/A
lighting12V(basedon10wbulb) N/A N/A 10w 0.8a N/A
Water Pump N/A N/A 48w 4a N/A
Cooker Hood N/A N/A 50w 4a N/A
Microwave oven 1000w 4.4a N/A N/A N/A
Similarly loadings on each circuit breaker
within the vehicle should be observed.
A label positioned close to the MCB’s will
identify which appliances within the vehicle
are fed from which MCB. Consulting the table
(Typical Appliance Consumption Figures) in
conjunction with this label, will give an indication
of which appliances can, and cannot, (site supply
allowing), be operated simultaneously.
WARNING: Never allow modifications of
electrical or LPG systems and appliances
except by qualified persons.
connecting services
wiring diagram
Wiring of connecting cable and motorhome mains inlet
WARNING: It is essential that connections are made exactly as shown. If terminal
markings are not in accordance with the diagram they must be ignored. If in doubt
consult a qualified electrician.
The legal length of the mains inlet cable is 25 ± 2 metres. When in use it must be fully
uncoiled and protected from traffic.
PITCH SUPPLY
OUTLET
CABLE PLUG
CABLE COUPLER
MOTORHOME
MAINS INLET
connecting services