Specifications
Truma Combi 4E / Truma Combi 6E
The Combi E gas heater is a warm air heater
with an integrated hot water boiler.
The unit can operate on liquid gas (LPG)
or 230V mains electricity.
The heater can be used in ‘winter’ mode that
will produce warm air heating and hot water,
and ‘summer’ mode that will produce hot
water only.
Before operating the heater for the first time
ensure that the 12V system is turned ‘ON’
on the control panel over the doorway,
and that the gas cylinder, and isolation
valve are turned on.
To use the heater on 230V the motorhome
must be plugged into the mains supply,
with the isolation switch in the ‘ON’ position.
Power Selector Switch
A Power selection rotary switch
B Electric operation 230V, 1800W
C Electric operation 230V, 900W
D Gas operation
E Mixed operation *
(gas and 900W electrical operation)
F Mixed operation *
(gas and 1800W electrical operation)
G Yellow LED on = “Electrical operation”
Position “E” and “F” should only be used in
‘winter’ mode.
Control Panel
H Rotary switch for room temperature (1 – 5)
J Green LED lit “Operating”
Green LED flashing = unit “after running”
to reduce the units temperature
K Summer operation
(water temperature either 40˚ or 60˚ )
L Winter operation (heating without hot water
or water system drained)
M Winter operation (heating with hot water)
N Rotary “OFF” switch
P Yellow LED lit – boiler heat up phase.
Q Red LED lit, red LED blinking = failure of
heater to ignite.
Please note that all LEDs are only visible
when the unit is switched on.
TAKE YOURS ON AN ADVENTURE
29
Truma Combi 4E / 6E
A
B
C
D
E
F
G
K
N
L
M
J
P, Q
H
2090 AT Cheyenne-Frontier Owners Handbook REPRO 2:Layout 1 18/11/08 14:40 Page 29