User manual
17
MC-III™ EXP Flow Analyzer Section 1
• To reset the total with an explosion-proof switch, press and hold the switch for 3 seconds, then release it.
See also Explosion-Proof Reset/Control Switch, page 15.
• To reset the total with an external pulse generator located in safe area, congure the pulse to be active for
3 seconds. See also Remote Reset Input, page 29.
Viewing Daily and Hourly Logs
Each day, as the user-dened contract hour passes, a daily ow total is saved to nonvolatile memory. Hourly
logs are also automatically saved. A total of 384 daily logs and 768 hourly logs are accessible for viewing and
exporting using the interface software. See Section 5, page 79, for details.
Up to 99 daily ow log totals can be viewed from the LCD. Hourly ow log totals are accessible only through
the interface software.
To view daily ow totals from the LCD, perform the following steps:
1. Press the LEFT ARROW (LOG) key on the keypad. The words “Daily Volume Archive” will scroll across
the bottom of the LCD and the day index will display “01.” The daily ow total recorded at the last con-
tract hour will appear at the top of the LCD.
The index number represents the number of days previous to the current date. For example, yesterday’s
totals are read by entering an index of “01”; totals from two days previous are read by entering “02.”
2. Press UP ARROW (TEST) to increment the index (01, 02, 03...); press LEFT ARROW (LOG) to decre-
ment the index (01, 99, 98...).
3. Press ENTER (SAVE) to exit the Daily Volume Archive menu. (After 2 minutes of inactivity, the Daily
Volume Archive menu will timeout and the total readout will be restored automatically.)
The optional explosion-proof reset switch also allows users to view daily log totals. For more information, see
Explosion-Proof Reset/Control Switch, page 15.
Saving and Uploading Conguration Files
The MC-III interface software allows users to save an unlimited number of conguration les to their
computer. In the event that a conguration setting gets changed unintentionally or a user simply wants to
restore the settings he used previously, the user can upload the conguration le and resume operation within
minutes. The upload function also allows a conguration le to be loaded quickly into multiple devices. The
default directory for saving conguration les is C:\NuFlo log data\MC-III. However, the user can specify a
different location, if desired.
For complete information, see Saving and Uploading Conguration Files, page 75.
Exporting Log Data
Flow logs and event logs can be directly exported to an .xls or .csv le. For complete information, see
Exporting Flow Logs, page 86, and Exporting Event Logs, page 89. The default directory for exported logs is C:\
NuFlo log data\MC-III. However, the user can specify a different location, if desired.
Saving Log Data in a Report
Flow logs can be saved in a report format that can be loaded back into the software for viewing or printing
at a later time. For complete information, see Printing/Saving a Report, page 89. The default directory for log
reports is C:\NuFlo log data\MC-III\<WELL NAME>. However, the user can specify a different location.