MC-III™ EXP Flow Analyzer Appendix D
The unit of measurement for this register is pulses per congured factor unit. Once the K-factor is calculated
based on frequency and K-factor points, this value is multiplied by 1000 if the user chooses to read the
volume in units x 1000, and it is divided by the Standard Measurement Correction Factor (register 2059).
Holding Registers (32-bit Mode)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
7000 1B58
Hourly Pointer
[1 to 768]
FP32 RO
7001 1B59
Daily Pointer
[1 to 384]
FP32 RO
7002 1B5A
Event Counter
[1 to 345]
FP32 RO
7003 1B5B
Real Date
(MM/DD/YY)
FP32 RO
7004 1B5C
Real Time
(HH:MM:SS)
FP32 RO
7005 1B5D
Grand Total
(in terms of congured volume units)
FP32 RO
7006 1B5E
Instantaneous Flow Rate
(in terms of congured ow rate units)
FP32 RO
7007 1B5F
Daily Total
(in terms of congured volume units)
FP32 RO
7008 1B60
Daily Run Time
(seconds)
FP32 RO
7009 1B61
Hourly Total
(in terms of congured volume units)
FP32 RO
7010 1B62
Hourly Run Time
(seconds)
FP32 RO
7011 1B63
Polling Total
(in terms of congured volume units)
FP32 RO
7012 1B64
Polling Run Time
(seconds)
FP32 RO
7013 1B65
Previous Day Total
(in terms of congured volume units)
FP32 RO
7014 1B66
Previous Day Run Time
(seconds)
FP32 RO
7015 1B67
Previous Hour Total
(in terms of congured volume units)
FP32 RO
7016 1B68
Previous Hour Run Time
(seconds)
FP32 RO
7017 1B69
Previous Polling Total
(in terms of congured volume units)
FP32 RO
7018 1B6A
Previous Polling Run Time
(seconds)
FP32 RO