User manual
D-13
MC-III™ EXP Flow Analyzer Appendix D
The unit of measurement for this register is pulses per congured factor unit. Once the K-factor is calculated
based on frequency and K-factor points, this value is multiplied by 1000 if the user chooses to read the
volume in units x 1000, and it is divided by the Standard Measurement Correction Factor (register 2059).
Holding Registers (32-bit Mode)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
7000 1B58
Hourly Pointer
[1 to 768]
FP32 RO
7001 1B59
Daily Pointer
[1 to 384]
FP32 RO
7002 1B5A
Event Counter
[1 to 345]
FP32 RO
7003 1B5B
Real Date
(MM/DD/YY)
FP32 RO
7004 1B5C
Real Time
(HH:MM:SS)
FP32 RO
7005 1B5D
Grand Total
(in terms of congured volume units)
FP32 RO
7006 1B5E
Instantaneous Flow Rate
(in terms of congured ow rate units)
FP32 RO
7007 1B5F
Daily Total
(in terms of congured volume units)
FP32 RO
7008 1B60
Daily Run Time
(seconds)
FP32 RO
7009 1B61
Hourly Total
(in terms of congured volume units)
FP32 RO
7010 1B62
Hourly Run Time
(seconds)
FP32 RO
7011 1B63
Polling Total
(in terms of congured volume units)
FP32 RO
7012 1B64
Polling Run Time
(seconds)
FP32 RO
7013 1B65
Previous Day Total
(in terms of congured volume units)
FP32 RO
7014 1B66
Previous Day Run Time
(seconds)
FP32 RO
7015 1B67
Previous Hour Total
(in terms of congured volume units)
FP32 RO
7016 1B68
Previous Hour Run Time
(seconds)
FP32 RO
7017 1B69
Previous Polling Total
(in terms of congured volume units)
FP32 RO
7018 1B6A
Previous Polling Run Time
(seconds)
FP32 RO