User manual
D-6
Appendix D MC-III™ EXP Flow Analyzer
Input Conguration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access Default
2002 07D2
Rate Volume Units
Units
0 = No Units
1 = Gallons
2 = Barrels
3 = Cubic Meters
4 = Cubic Feet
5 = Liters
Units × 1000
16 = No Units
17 = Gallons
18 = Barrels
19 = Cubic Meters
20 = Cubic Feet
21 = Liters
U16 R/W 2
Standard Units
32 = No Units
33 = Gallons
34 = Barrels
35 = Cubic Meters
36 = Cubic Feet
37 = Liters
Std. Units × 1000
48 = No Units
49 = Gallons
50 = Barrels
51 = Cubic Meters
52 = Cubic Feet
53 = Liters
2003 07D3
Rate Time Base
0 = Second
1 = Minute
2 = Hour
3 = Day
U16 R/W 3
2004 07D4
Rate Decimal Point Location
0 = No digits to the right of the decimal point
1 = Tenths
2 = Hundredths
3 = Thousandths
U16 R/W 2
2005 07D5
Calculation Period
(sec)
U16 R/W 4
2006 07D6
Turbine Meter Input Conguration
0 = Pulse Input
1 = TFM - LOW
2 = TFM - MED
3 = TFM - HIGH
U16 R/W 1
2007 07D7
Low Frequency Cut-Off Threshold
(Hz)
U16 2
2008 07D8
Factor Type
1 = 1-Point K-Factor
2 = 2-Point K-Factor
…
12 = 12-Point K-Factor
U16 R/W 1