User manual

B-6
Appendix B MC-III™ EXP Flow Analyzer
To save the logs in .xls format, check the “XLS-MS Excel File” checkbox (Figure B.5, page B-5). Additional
checkboxes allow for changes in the appearance of downloaded log data.
Users can also export ow data to a .csv or .xls le as needed. For complete information, see Exporting Flow
Logs, page 86.
Advanced Options
Clear EEPROM
The Clear EEPROM function will erase all conguration settings and log data. This task is typically
performed when updating to a new rmware version or before moving the instrument to a new site. To clear
the memory, click on the “Clear EEPROM” button (Figure B.6).
Technical assistance is typically required for upgrading rmware. Contact Cameron’s Measurement Systems
Division to arrange an upgrade.
!
WARNING: Clicking the “Clear EEPROM” button will delete all conguration settings and log
records in the MC-III EXP memory.
Figure B.6—Menu for clearing EEPROMs and enabling automatic data logs
Automatic Data Logging
Data retrieved from the MC-III EXP while in Advanced access mode can be logged to a le by enabling
the “Automatically log data polls” checkbox on the Advanced Options screen. To specify the lename and
location of the le, click the folder icon on the right of the Data logging lename eld. The le will include
values that are retrieved from the instrument when the user clicks the “Get All Data” button or enables “Auto
Polling” on the Advanced Access screen. See also Advanced Access, page 78.