Specifications

________________________________________________________________________________
MYGate call[-"n"] Default: none
Mode: Packet Host: MY
_________________________________ Parameters: __________________________________
call - The Call Sign you wish to use for the Gateway.
"n" - Numeral indicating an optional substation ID (SSID) or extension.
________________________________________________________________________________
Call is the call sign of the Gateway, default "none."
"Call" may have an optional SSID, and must not be the same call sign and SSID as
MYCALL or MYMAIL. When another station digipeats via the callsign set in
MYGATE, your PK-900 will provide Gateway operation between Radio Port 1 and
Radio Port 2 provided both ports are enabled for Packet operation.
See Chapter 4 for details of Gateway operation and limitations.
________________________________________________________________________________
MYMail call[-"n"] Default: none
Mode: Packet, PACTOR/MailDrop Host: Ma
_________________________________ Parameters: __________________________________
call - The Call Sign you wish to use for the MailDrop.
"n" - Numeral indicating an optional substation ID (SSID) or extension.
________________________________________________________________________________
Call is the call sign of the MailDrop, default "none."
"Call" may have an optional SSID, and must not be the same call sign and SSID as
MYCALL. If you do not set MYMAIL, the MailDrop will use the same call sign and
SSID as entered in MYCALL. For example, if you have set MYCALL to N7ML then
MYMAIL may be N7ML-1 through N7ML-15. You can use the CTEXT and MTEXT messages
to inform other stations who connect of your MYCALL and MYMAIL call signs.
_________________________________________________________________________________
MYPTcall call Default: PK900
Mode: PACTOR Host: Mf
________________________________________________________________________________
Use the MYPTCALL comand to load your call sign into your PK-900. Only radio
port 1 will operate on PACTOR.
If you have not loaded a call into the PK-900 with MYPTCALL the call loaded
in MYCALL will be used. The difference between MYCALL and MYPTCALL is that
MYCALL allows only the dash (-) to be used while MYPTCALL will allow any
punctuation with the call.
If calls have not been loaded into either MYCALL or MYPTCALL, the PK-900 will
not allow transmission on PACTOR. An error message "Need MYCALL" will be
displayed if transmission is attempted.
3/93 A-74