Service manual

6 Troubleshooting
6-6 SAM4S ER-900/SPS-300 SERIES
6-7 Main B’D problem (Key Board, Mode key, Drawer, MCR, Dallas-key)
6-7-1 Key Board & Mode Key
Key Board Operation Fail
Check the FPC harness between Key Board and Main B’D.
Check the key scan part (74LVC138, U21, U23, U24) and key return part(74LVC541, U28).
Change the Key Board Ass’y
Check related circuit & component whether short or not.
Mode key Operation Fail
Check the harness between Key Board and Main B’D.
Check the harness between Key Board and Mode Key Assy.
Check the key return part(74LVC541, U28).
Change the Mode Key Assy
Check related circuit & component whether short or not.
6-7-2 Drawer & Compulsory
Drawer Operation Fail
Check the harness between I/F B’D and Main B’D.( Wire harness 14pin)
Check Drawer specification whether it is +24V drawer or not.
Check the cable. Refer to Chapter 2 for cable connection.
Check related circuit & component whether short or not.
Compulsory Fail
Check the cable and compulsory connector.
Check the micro switch in the Drawer.
6-7-3 MCR (Magnetic Card Reader)
Operation Fail
Check the harness between MCR and Main B’D, if it is connected or not.
Check the IC- Buffer chip (74LVC541, U35).
Check the CPU on Main B’D whether it works normally or dead.
Check related circuit & component whether short or not.
6-7-4 Dallas-Key
Operation Fail
Check the harness between Dallas-Key and Main B’D, if it is connected or not.
Check the CPU on Main B’D whether it works normally or dead.
Check related circuit & component whether short or not.
If these are OK above but Dallas-Key does not work, Please contact our R&D.