Service manual
5-49
4. Y OUT Level Adjustment (VC-215 board)
Set the Y signal output level.
Mode VTR stop
Signal No signal
Measurement Point VIDEO terminal (75Ω terminated )
Measuring Instrument Oscilloscope
Adjustment Page F
Adjustment Address 49
Specified Value A = 286±5mV
Note 1 : Hi8 model
CCD-TR516/TR516PK/TR716
CCD-TRV36/TRV36PK/TRV43/TRV46/TRV46PK
: Standard8 model
CCD-TR315/TR416/TR416PK
CCD-TRV16/TRV16PK
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 61, and set data: 30, and press the PAUSE
button of the adjusting remote commander.
4) Select page: F, address: 49, change the data and set the SYNC
level (A) to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 2, address: 61, and set data: 10.
7) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-8.
5. C OUT Level Adjustment (VC-215 board)
Set the chroma signal output level.
Mode VTR stop
Signal No signal
Measurement Point VIDEO terminal (75Ω terminated )
Measuring Instrument Oscilloscope
Adjustment Page F
Adjustment Address 4B
Specified Value A = 286±5mV
Note 1 : Hi8 model
CCD-TR516/TR516PK/TR716
CCD-TRV36/TRV36PK/TRV43/TRV46/TRV46PK
: Standard8 model
CCD-TR315/TR416/TR416PK
CCD-TRV16/TRV16PK
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 61, and set data: 30, and press the PAUSE
button of the adjusting remote commander.
4) Select page: F, address: 4B, change the data and set the burst
level (A) to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 2, address: 61, and set data: 10.
7) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-9.
Hi8 model
Standard 8 model
A
H
Hi8 model
Standard 8 model
A