User guide

Chapter 5. Installing the Display System
Street Dash Users Guide 35
VSS Pulse Amplifier Technical Specification
Supply : From system input
Output characteristics : compatible with system
Input impedance : >50K Ohms
Operating temperature range : -4 to 176 ºF
Input threshold adjustment range : -5 Volts to +12 Volts
Input hysteresis : +/- 0.1 Volt
Maximum input frequency 2000 Hertz
Physical dimensions : (mm) L 51, H 18, W 32
(in) L 2, H ¾, W 1¼
Weight : 50g / 2oz maximum
Vibration testing : 20 G, 50Hz to 2000Hz,
1 Octave/min for 12 hours
Fuel Tank Sender
Plug the adapter supplied in the sensor bag to the 4-way sure seal
connector marked F.
Single-Wire Sender
If your vehicle is fitted with a single-wire sender (rheostat),
remove the existing wire from it and connect the red (F) wire to
it.
Two-Wire Sender
If your vehicle is fitted with a two-wire sender (potentiometer),
remove the existing wires and fit the red (F) wire to one of the
terminals. If there is no change in fuel-level reading during
calibration, fit the red wire to the other terminal.
In some cases, it may be necessary to attach a grounded wire to
your fuel sender mounting flange for proper operation.