User guide

Chapter 4. Configuring the Display System
18 Street Dash Users Guide
Configurable Parameters
The configurable parameters are displayed in the following
order:
Configurable
Parameter
Setting Required Switchable
Parameter
Shift RPM RPM at or above which the gear shift
light is to come on
Yes
Low Fuel Volume of fuel in tank at or below which
the low fuel warning light is to be turned
on.
Yes
High OiI T Oil temperature at or above which the
High Oil Temperature alarm is to be
signalled.
Yes
High Water Water temperature at or above which the
High Water alarm is to be signaled.
Yes
Low Batt Battery voltage at or below which the
Low Batt alarm is to be signaled.
Yes
Low Fuel P
(optional)
Fuel pressure at or below which the Low
Fuel Pressure alarm is to be signaled.
Yes
Low Oil P Oil pressure at or below which the Low
Oil Pressure alarm is to be signaled.
Yes
Fuel Tank
Sender
The volume of fuel currently in the tank.
See "Calibrating the Fuel Level" on page
22 for more details.
Not applicable
Gate RPM Minimum RPM for oil temperature, oil
pressure and water temperature
warnings to operate.
Yes
E. S. Cylinders Number of cylinders in engine (for RPM) Not applicable
W.S. Pulses/Rev See “Wheel Pulses and Circumferences”
on page 21 for more details.
Not applicable
Wheel Cir See “Wheel Pulses and Circumferences”
on page 21 for more details.
Not applicable