Service manual

Model 5304A
Maintenance
CHECK MODE
5304A Controls:
COM/SEP/CHK
to CHK;
"Function"
to
AUTO
5300A Display should
be
10.0000
MHz C ±1
count.
Oscilloscope:
HP 180A, HP 1801A
Vert
Amp, HP 1821A T.B.
through
a 10:1
probe
Settings:
AC
coupled (except
as
noted).
NORM sweep mode.
+
Slope (except
as
noted).
AC
(except
as
noted).
Channel
A.
9D-5-14