Owner`s manual

10/09
BASIC OPERATION
Air is drawn through the intake filter,
intake manifold and suction discs into
the cylinders. The air is compressed,
then discharged through the delivery
discs to the temperature reducer, where
the heat of the compressed air is partly
removed. From the temperature reducer
the compressed air is discharged
through the 5/8” JIC customer
connection points.
AUTO RUN MODE
When the demand for air is moderate, the
unit should be run in the auto mode.
This allows the compressor to produce
air until the pressure reaches the upper
limit of the pressure switch and stop. At
this point it shuts the compressor off.
When the tank pressure reduces to the
lower limit of the pressure switch the
unit will start up and continue producing
air.
CAUTION: When the hydraulic system
shuts down a shock wave is delivered to
the return line. Locate the hydraulic
coolers and filters a minimum of 10’
away.
The pressure switch is preset to
specified settings.
Pressure Switch:
Shutoff: 150 psig
Restart: 110 psig
1-4.0.0
OPERATION — AC30A