Owner`s manual

10/09
1 Locate air pump in a well ventilated
area on truck body.
2 Secure to truck body through
bottom side rails using four
(4) 3/8- 24 NF x 2¾ Grade 5 bolts.
Four (4) new 7/16 diameter holes
may be made in the side frame rail
to allow for obstruction problems.
3 Remove plastic cap from “T” port in
the hydraulic valve block and install
return line to cooler or reservoir.
4 Remove plastic cap from “P” port
in the hydraulic valve block and
install pressure line from hydraulic
pump.
5 The mating electrical connector has
4 wires. Red, black and orange. Run
red power wire to a 10 amp fused
switched ignition source. The black
to a frame ground source. The
orange wire is optional and is a
power feed source from the
compressor when the compressor is
running only. This is a 10 amp max.
power feed.
6 Attach air hose to the straight 5/8"
fitting (37 degree JIC male) on the
compressor discharge line.
7 Follow initial start-up procedure.
1-3.0.0
AC30A
INSTALLATION INSTRUCTIONS