Owner`s manual

10/09
1 Read the AC30A Owner’s Manual.
2 Check all wiring for loose
connections.
3 Check oil level in sight gauge. It
should be filled to the middle of the
sight glass. If not, fill to the proper
level. Fill with PAO synthetic
lubricant equivalent to Chevron-Gulf
GSL 838A or Summit SH-46. If
petroleum based crankcase oil is
required by operator, use an SAE
10W oil, API classification CD of SF,
Mil Spec MIL-L-2104C or MIL-L-46152.
CAUTION: Do not mix oil types.
4 Check that pressure switch operates
at the pressure limits specified.
5 Check the oil fill cap on top of
compressor (yellow knob) for
tightness.
6 Check hydraulic fluid flow.
CAUTION: More than 12 GPM will
build excess heat in the system.
7 Check all piping for leaks.
1-5.0.0
AC30A