Specifications

. A complete Parts List is available at www.HobartWelders.com
OM-243 712 Page 15
5-7. Connecting 115 Volt Input Power
! Installation must meet all
National and Local Codes
have only qualified persons
make this installation.
! Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
For 115 volts AC input power, a 20
ampere individual circuit protected
by time-delay fuses or circuit
breaker is required.
1 Plug From Unit
2 Receptacle − NEMA Type
5−15R (Customer Supplied)
Select extension cord of 12 AWG
for up to 50 ft (15 m) or 10 AWG for
50 up to 100 ft (30 m).
Input6 2011−03 / 803 443-C
1
2
5-8. Installing Contact Tip And Nozzle
Tools Needed:
Ref. 804 241-A
! Turn off welding power source.
1 Nozzle
Remove nozzle.
2 Contact Tip
3 Tip Adapter
Thread welding wire through gun (see
Section 5-9).
Slide contact tip over wire and tighten
tip into tip adapter.
Install nozzle.
Flux Nozzle
MIG Nozzle
Use with flux cored wire only. Narrow
design allows access in tight spaces
and provides better visibility of
puddle during welding.
Use with solid or flux cored wire.
Push nozzle over contact tip and
adapter until it is seated onto adapter.
Contact tip will be exposed
approximately 7/16 in. (11.3 mm)
when installed properly.
Push nozzle over contact tip and
adapter until it is seated onto
adapter. End of contact tip will be
flush with end of nozzle when
installed properly.
1
2
3