Full Product Manual

30
Yellow LED
short, long, short beep
Red LED
Four short beeps
After you have read the information, press ENTER/Exit to exit. The other
buttons are disabled to prevent misoperation.
Retrieve I/M Readiness Status in Typical Way
1) Use the SCROLL button to select I/M Readiness from Diagnostic
Menu and press ENTER/Exit button.
2) Wait while the scan tool validates the PID MAP.
3) If the vehicle supports both types of tests, then both types will be
displayed on the screen for selection.
Figure 3-14
4) Use the SCROLL button to view the status of the MIL light (ON or OFF)
and the following monitors.
For spark ignition engines:
MIS Misfire Monitor
FUEL Fuel System Monitor
CCM Comprehensive Component Monitor
EGR EGR System Monitor
O2S O2 Sensors Monitor
CAT Catalyst Monitor
EVAP Evaporative System Monitor
HTR O2 Sensor Heater Monitor
AIR Secondary Air Monitor
HCAT Heated Catalyst Monitor