40
Injection Rate
This function is used to adjust the injection volume.
1) Select Injection Rate from the service functions menu (Figure 5-20)
and press OK.
2) The tool communicates with the vehicle and reads the fault codes
memory. Follow the on-screen instructions to finish this procedure.
3) Then the tool will display as below. Press the corresponding number
button to perform the desired function.
Figure 5-23 Sample Injection Rate Screen
[1] Enter New Value for Adjustment
From the Injection Rate menu (Figure 5-21), select [1] and press OK. The
screen displays as below.