User Manual
Table Of Contents
- Trademarks
- Copyright Information
- Disclaimer of Warranties and Limitation of Liabilities
- For Services and Support:
- Safety Information
- Chapter 1 Using This Manual
- Chapter 2 General Introduction
- Chapter 3 Getting Started
- Chapter 4 Diagnostics Operations
- Chapter 5 TPMS Service Operations
- Chapter 6 MaxiFix Operations
- 6.1 Navigation
- The Header
- Select Vehicle Button
- The “Select Vehicle” button on the Header allows you to specify the vehicle which you want to reference on MaxiFix, by selecting each of the vehicle attribute from a sequence of option lists. This feature helps to filter out the searches that allow on...
- 6.1.1 Terminology
- 6.2 Operations
- 6.1 Navigation
- Chapter 7 Shop Manager Operations
- Chapter 8 Data Manager Operations
- Chapter 9 Settings Operations
- Chapter 10 Update Operations
- Chapter 11 VCI Manager Operations
- Chapter 12 Support Operations
- Chapter 13 Training Operations
- Chapter 14 Remote Desk Operations
- Chapter 15 Quick Link Operations
- Chapter 16 Oscilloscope Operations
- 16.1 Safety Information
- 16.2 Glossary
- 16.3 MaxiScope Module
- 16.4 Screen Layout and Operations
- 16.4.1 Top Toolbar
- Math Channel
- A math channel is virtual channel generated by mathematical function of the input channel. It can be displayed in a scope in the same way as an input signal, and like an input signal it has its own measure axis, scaling and color. The MaxiScope module...
- Probe
- A probe is any transducer, measuring device or other accessory that you connect to an input channel of your MaxiScope module.
- Reference Waveform
- Recall Reference
- 16.4.2 Functional Buttons
- 16.4.3 Measurement Grid
- 16.4.4 Measurement Rulers
- 16.4.5 Functional Buttons
- 16.4.1 Top Toolbar
- 16.5 Troubleshooting
- 16.6 MaxiScope Firmware Update
- Chapter 17 Digital Inspection Operations
- Chapter 18 Maintenance and Service
- Chapter 19 Compliance Information
- Chapter 20 Warranty
Oscilloscope Operations Troubleshooting
129
B. Auto Mode - configures the trigger to occur every time when the
scope captures the signal waveforms by the preset trigger point.
The scope continues to draw the waveforms even when the signal
is not in the trigger point range.
Main Time Base – allows users to select an appropriate time per division.
The time per division (10 divisions) is displayed along the bottom of the
screen. The time base adjustment affects all of the active scope
channels at once.
Measure - allows users to select various types of measurement
parameters to be displayed at the right side of the screen for reference.
A maximum of 5 items each time are allowed to be selected.
To set a specific trigger point
1. Tap the Trigger On button to activate the trigger.
2. Configures the specific trigger source, the trigger slope and the
trigger mode according to the test demand.
3. Tap and slide the voltage scale reference line up or down to the
desired voltage point. The voltage info is displayed in a small
reference box.
4. Tap and slide the time base reference line left or right to the desired
point.
5. Tap Start button on the top right side of the screen to activate the
scope
16.5 Troubleshooting
If the MaxiScope is not communicating with the Display Tablet, you need to do
the followings:
Check if the MaxiScope is properly connected to the Display Tablet
through the supplied USB cable.
If the MaxiScope is already connected to the Display Tablet, but the
communication between the devices has failed, tap the Scope Icon
on the top right side of the screen to reset the USB connection.