- 6.1 Navigation
- The Header
- Select Vehicle Button
- The “Select Vehicle” button on the Header allows you to specify the vehicle which you want to reference on MaxiFix, by selecting each of the vehicle attribute from a sequence of option lists. This feature helps to filter out the searches that allow on...
- 6.1.1 Terminology
- 6.2 Operations
- 6.1 Navigation
- Chapter 7 Shop Manager Operations
- Chapter 8 Data Manager Operations
- Chapter 9 Settings Operations
- Chapter 10 Update Operations
- Chapter 11 VCI Manager Operations
- Chapter 12 Support Operations
- Chapter 13 Training Operations
- Chapter 14 Remote Desk Operations
- Chapter 15 Quick Link Operations
- Chapter 16 Oscilloscope Operations
- 16.1 Safety Information
- 16.2 Glossary
- 16.3 MaxiScope Module
- 16.4 Screen Layout and Operations
- 16.4.1 Top Toolbar
- Math Channel
- A math channel is virtual channel generated by mathematical function of the input channel. It can be displayed in a scope in the same way as an input signal, and like an input signal it has its own measure axis, scaling and color. The MaxiScope module...
- Probe
- A probe is any transducer, measuring device or other accessory that you connect to an input channel of your MaxiScope module.
- Reference Waveform
- Recall Reference
- 16.4.2 Functional Buttons
- 16.4.3 Measurement Grid
- 16.4.4 Measurement Rulers
- 16.4.5 Functional Buttons
- 16.4.1 Top Toolbar
- 16.5 Troubleshooting
- 16.6 MaxiScope Firmware Update
- Chapter 17 Digital Inspection Operations
- Chapter 18 Maintenance and Service
- Chapter 19 Compliance Information
- Chapter 20 Warranty
Oscilloscope Operations Screen Layout and Operations
128
Figure 16-8 Measurement Rulers Display
16.4.5 Functional Buttons
This group of buttons includes trigger setting buttons allowing you to set
trigger source and trigger mode, a Time base button for adjustment, and a
Measurement button with options for various measurement types.
Trigger On/Off – taps to turn on/off the trigger. The button displays as
Trigger Off when it is activated, and vice versa.
Once the trigger is activated, a voltage scale reference line and a time
base reference line will be displayed on the measurement grid, the cross
point of the 2 lines indicates the trigger point, allowing users to adjust its
position by moving each of the 2 lines.
Trigger Source – assigns the trigger to a specific channel
Trigger Slope – sets trigger to occur by rising or falling voltage edges
Trigger Mode – configures the trigger mode:
A. Normal Mode – configures the trigger to occur every time when the
captured signal waveform reaches the trigger point, so the scope
starts to draw the waveform when the signal reaches the trigger
point.