User Guide
Additional Features
The following features protect and extend battery life.
• Storage self-discharge protectionIf the battery is stored in a
hot environment or not used for 6 days and the charge level is
high, the self-discharge protection will be activated. The battery
will be automatically discharged to a safe level. This is the default
setting, and the discharge process takes 2-3 days. Although the
battery does not indicate during the self-discharge cycle, you may
notice a slight warming of the battery, which is normal.
• Low power protectionIf the battery is low, it will automatically
enter sleep mode to prevent over-discharge. In this mode, the
battery does not respond when the power button is pressed. To
wake up the battery, connect it to the charger.
• Charging temperature detectionIf the temperature is below 5(41)
or above 45(113) when charging, the battery will stop charging.
• Overcurrent protectionWhen the charging current is too high,
the battery will stop charging.
• Overcharge protectionCharging will stop automatically when
the battery is fully charged.
• Balance protectionThe voltage of each battery cell is balanced
to prevent overcharging or over-discharging.
• Over-discharge protectionWhen the battery is not in use, it
will automatically disconnect the power output function after
the self-discharge cycle is completed. This function is disabled
during flight.
• Short circuit protectionOnce a short circuit is detected, the
power will be cut off.
• Power saving modeIf there is no operation for 30 minutes, the
battery will turn off.