User Manual
Table Of Contents
- Trademarks
- Copyright Information
- Disclaimer of Warranties and Limitation of Liabili
- For Services and Support:
- Safety Information
- Chapter 1 Using This Manual
- Chapter 2 General Introduction
- Chapter 3 Getting Started
- Chapter 4 Diagnostics Operations
- Chapter 5 Data Manager Operations
- Chapter 6 ADAS
- Chapter 7 MaxiFix Operations
- Chapter 8 Settings Operations
- Chapter 9 Shop Manager Operations
- Chapter 10 Update Operations
- Chapter 11 VCI Manager Operations
- Chapter 12 Remote Desk Operations
- Chapter 13 Support
- Chapter 14 Academy
- Chapter 15 Quick Link Operations
- Chapter 16 MaxiScope Operations
- Chapter 17 Function Viewer
- Chapter 18 Digital Inspection Operations
- Chapter 19 Maintenance and Service
- Chapter 20 Compliance Information
- Chapter 21 Warranty
100
Chapter 16 MaxiScope Operations
The MaxiScope application configures the MaxiCOM Diagnostic Device to operate as
an automotive oscilloscope when work in combination with the MaxiScope module. This
function provides all the features needed for performing electrical and electronic circuit
tests as well as monitoring signal activities on any modern vehicles, which shows you
what is really going on with a vehicle’s electrical system.
Please download the latest user manual for Autel MaxiScope device from
www.autel.com.
16.1 Safety Information
Follow these instructions to reduce the risk of injury from electric shock and prevent
equipment damage.
A. Maximum input ranges
Observe all terminal ratings and warnings marked on the product.
DANGER:
To prevent electric shock, operate within the safe input range for the scope,
refer to 16.1 Safety Information on page 100.
To prevent electric shock, take all necessary safety precautions when
working on equipment where voltages above the specified input range may
be present. Contact with voltages outside of the specified measuring range
presents a risk of electric shock.
To prevent injury or death, the oscilloscope must not be directly connected to
the mains (line power). To measure mains voltages, use a differential
isolating probe specifically rated for mains use.
WARNING:
Operation outside of the safe input range is likely to cause permanent
damage to the oscilloscope and other connected equipment.
B. Grounding
DANGER:
The scope’s ground connection through the USB cable is for measurement
purposes only. The oscilloscope does not have a protective safety ground.
Do not connect the ground input (chassis) to any electrical power source. To