Product Manual

8
Additional Functions
The smart functions listed below will give you a full understanding of the aircraft
battery and how to protect and preserve the battery life.
Storage Self-Discharge Protection: In order to prevent damage, after the
battery has been idle for 6 days and the voltage is higher than 12V, the battery
will discharge automatically to approximately 70% of total power. This is the
default setting, and the discharge process takes 2-3 days. While there’s no
formal indication that the battery is performing a self-discharge cycle, you
may notice a slight warming of the battery, which is normal. The discharge
threshold can be customized using the Autel Explorer
TM
app.
Charging Temperature Detection: The normal charging temperature should
be between 10°C (50°F) and 45°C (113°F), the battery will stop charging if the
temperature exceeds this range.
Overcurrent Protection: The battery will stop charging if the charging current
exceeds 8A to prevent severe damage.
Overcharge Protection: Charging will stop automatically when the battery
reaches full charge.
Balance Protection: Balances the voltage of each battery cell to prevent
overcharging or over-discharging.
Over-Discharge Protection: When the battery is not in use, it will
automatically disconnect the power output function once the self-discharge
cycle is completed. This function is disabled during ight.
Short Circuit Protection: The power supply will be cut off in the event that a
short circuit is detected.
Power Saving Mode: After 30 minutes of inactivity, the battery will disconnect
from the power supply and enter power saving mode to retain the energy.
Communication: When in use, the aircraft continuously syncs with the
battery to provide real-time information including voltage, capacity, current,
and temperature.
Ultra-Low Power Consumption Mode: When idle for 7 days with a voltage
lower than 11.7V, the battery will enter this mode in order to conserve power.
It will resume normal function after being connected to the charger.