Chapter 6 MaxiFix Operations The MaxiFix application launches the on-line troubleshooter database, which not only provides you virtually all common diagnostic trouble code (DTC) database for most vehicles, but also serves as a forum allowing you to network with other MaxiSys users, and gives you access to a vast database of repair and diagnostic tips along with proven filed fixes.
MaxiFix Operations Navigation The MaxiFix screen layout consists of 3 main areas: 1. The Header –the tool bar across the top of the screen which allows you to select vehicles and perform searches. 2. The Main Screen –located at the center of the screen displaying content based on the vehicle attributes and keywords specified. The tabs on the main screen vary in accordance with the section selected on the Navigation Menu, allowing you to switch between functions. 3.
MaxiFix Operations Navigation 5. Select the submodel of the vehicle from the list. 6. Select the engine of the vehicle from the list. After completing the vehicle selection procedure, the identified vehicle is shown on the Header. 6.1.1 Terminology MaxiFix Tip A MaxiFix Tip provides practical information of real fix of a specific vehicle repair issue with detailed descriptions.
MaxiFix Operations Operations a) OBDII Fault Codes description and reference—helps in diagnostic assessment by making clear the nature of an automotive problem so that beginner and advanced technicians can make effective repairs b) Real Fix Tips—provides repair tips from actual shop practices and are presented in an easy to understand Complaint, Cause, Correction format.
MaxiFix Operations Operations to your activities in the Question section. Support – opens the FAQ page, or a message box for contacting Customer Service by email. 6.2.1 Home Home is the first option on the Navigation Menu at the bottom of the screen. Tapping it opens your MaxiFix home page. There is a list of questions posted on the community, and you can scroll down the page to the bottom and view more questions by tapping “View More”.
MaxiFix Operations Operations To ask a MaxiFix Question 1. If not already done, click Select Vehicle on the Header to specify the vehicle you are asking about. 2. Click Ask on the Navigation Menu at the bottom of the screen to open the Ask page. 3. On the Ask page find Ask for Help, fill in the following sections to ask a question. The Ask page has 4 sections: Subject – this is where you enter a brief subject for the question.
MaxiFix Operations Operations Marked Posts – opens a list with links to Tips and discussions that you are actively participating in. My Profile –allows you to view your Autel account information including: your Autel ID, personal information, MaxiFix score, phone number and register time, and edit your portrait. Vehicle Preference –used to set up a list of preferred vehicles.
MaxiFix Operations Operations View Profile Information You can view your personal profile by clicking on your account ID or “My Profile” in My MaxiFix section or edit portrait where applicable, and visit other community members’ profile by clicking their portrait. Information included in your profile determines how you are presented to the community, and what type of information will be sent to you from the community. 6.2.
MaxiFix Operations Operations Close a Question When a repair question that you've posted to the community is resolved, you are encouraged to write down the case as a way to share a good solution. This will help the other MaxiFix members to find useful information for practical fix. To close a question, you need to select the question’s response message from the message list on “My Messages” page first, then tap “Adopted Answer” and select “Close Question”.
Chapter 7 Shop Manager Operations The Shop Manager application helps you to manage the workshop information, customer information records, and keep test vehicle history records, which can be a great assist in dealing with daily workshop business and improves customer service.
Shop Manager Operations Button Name Description History Notes Vehicle History Done 7.1 Vehicle History Touching this button opens a note form, which allows you to create audio record, attach picture or video, or edit text notes, etc. Touching this button opens the Vehicle History screen which displays the correlated test vehicle records. Complete editing and save the file.
Shop Manager Operations Vehicle History To activate a test session for the recorded vehicle 1. Tap the Shop Manager application on the MaxiSys Job Menu. 2. Select Vehicle History 3. Tap the Diagnostics button at the bottom of the thumbnail of a vehicle record item. Or, 4. Select a vehicle record item by tapping the thumbnail. 5. A Historical Test record sheet displays, check the recorded information of the recorded test vehicle, and tap the Diagnostics button on the upper right corner. 6.
Shop Manager Operations Workshop Information To edit the Historical Test record sheet 1. Tap the Shop Manager application on the MaxiSys Job Menu. 2. Select Vehicle History. 3. Select the specific vehicle history record thumbnail from the main section. The Historical Test record sheet displays. 4. Tap the Edit button to start editing. 5. Tap on each item to input the corresponding information or add attaching files or images.
Shop Manager Operations Customer Manager Figure 7-3 Sample Workshop Information Sheet 7.3 To edit the Workshop Information sheet 1. Tap the Shop Manager application on the MaxiSys Job Menu. 2. Select Workshop Information. 3. Tap the Edit button on the top toolbar. 4. Tap on each field to input the appropriate information. 5. Tap Done to save the updated workshop information sheet, or tap Cancel to exit without saving.
Shop Manager Operations 4. Customer Manager Tap the □ + photo frame beside the Name chart to add a photo. A sub menu displays, select Take Photo to take a new photo for the account, or select Choose Photo to choose from the existing files. 5. Some customers may have more than one vehicle for service; you can always add new vehicle information to the account to be correlated. Tap Add New Vehicle Information, and then fill in the vehicle information. Tap the ○ x button to cancel adding. 6.
Shop Manager Operations Customer Manager 7.3.1 History Notes The History Notes function allows you to add audio and video records, text notes and photos, to keep multi-media work logs for the associated customer account, which can be very helpful when dealing with repeat customers. Keeping notes for each vehicle serviced for each customer will keep you always on track and well organized in business. To access History Notes 1. Tap the Shop Manager application on the MaxiSys Job Menu. 2.
Shop Manager Operations Customer Manager Table 7-2 Function Buttons in History Notes Button Name Description Back Returns to the previous screen. Delete Touching this button deletes the selected note. Search Quickly locates the required note by entering the note title. Cancel Touching this button to cancel edit or file search. Edit Add Notes Audio Record Add Photos Take a Video Touching this button opens an edit window allowing you to edit notes and attach files.
Chapter 8 Data Manager Operations The Data Manager application is used to store, print, and review the saved files. Most operations are controlled through the toolbar. Selecting the Data Manager application opens the file system menu. Different file types are sorted separately under different options, there are six types of information files to be viewed or played back. Figure 8-1 Sample Data Manager Main Screen 8.1 Operations Data Manager Operations are based on toolbar controls.
Data Manager Operations Operations Figure 8-2 Sample Image Database Screen 1. Toolbar Buttons – used to edit, print and delete the image files. See Table 8-1 Toolbar Buttons in JPG Database on page 85 for detailed information. 2. Main Section – displays the stored images. Table 8-1 Toolbar Buttons in JPG Database Button Name Description Back Returns to the previous screen. Enter Edit Tapping this button shows the editing toolbar to print, delete or view image information.
Data Manager Operations Operations To edit image information 1. Select Data Manager application from the MaxiSys Job Menu. 2. Select Image to access the JPG database. 3. Select an image to display it in full screen. 4. Tapping the screen once displays the editing toolbar. 5. Tap the Info button to open a window displaying the image information. 6. Tap the Edit button on the top right corner of the window. The editing screen displays. 7.
Data Manager Operations Operations 8.1.3 Review Data The Review Data section allows you to playback the recorded data frames of live data streams. On the Review Data main screen, select a record file to playback. Figure 8-3 Sample Data Playback Screen 1. Drop-down Toolbar – tap the button at the top center of the screen to open the Drop-down Toolbar 2. Main Section – displays the recorded data frames 3.
Data Manager Operations Operations 8.1.5 Data Logging The Data Logging section allows you to launch Support platform directly to view all records of all sent or unsent (saved) data loggings on the diagnostic system. For more details, please refer to12.5 Data Logging 12.5on Page 104.
Chapter 9 Settings Operations Selecting Settings application opens a setup interface, on which you can adjust default setting and view information about the MaxiSys system. There are seven options available for the MaxiSys system settings: Unit Language Printing Setting Notification Center About System Settings 9.1 Operations This section describes the operation procedures for the settings. 9.1.1 Unit This option allows you to adjust the measurement unit for the diagnostic system.
Settings Operations Operations To adjust the language setting 1. Tap the Settings application on the MaxiSys Job Menu. 2. Tap the Language option on the left column. 3. Select the required language. A tick icon will display to the right of the selected language. 4. Tap the Home button on the top left corner to return to the MaxiSys Job Menu. Or select another setting option for the system setup. 9.1.
Settings Operations Operations 2. Tap the Notification Center option on the left column. 3. Tap the ON/OFF button to enable or disable the Notifications function. If the function is enabled the button turns blue, or if disabled the button turns gray. 4. Tap the Home button on the top left corner to return to the MaxiSys Job Menu. Or select another setting option for the system setup.
Settings Operations Operations 3. Tap the App Switcher option on the left column. 4. Mark the checkbox beside “Always show the App Switcher” on the right side of the screen, then the App Switcher icon shows. Short pressing the App Switcher icon opens a control panel: Tapping a specific app shortcut button enables you to switch directly to the selected application screen. Long pressing a specific app shortcut button displays the app menu, on which you can select and change the app shortcut.
Chapter 10 Update Operations The Update application allows you to download the latest released software. The updates can improve the MaxiSys applications’ capabilities, typically by adding new tests, new models, or enhanced applications to the database. The Display Tablet automatically searches for available updates for all of the MaxiSys software when it is connected to the internet. Any updates that are found can be downloaded and installed on the device.
Update Operations Operations Figure 10-2 Sample Update Screen – for MaxiSys MS906BT 1. 2. 3.
Update Operations Operations Right Column – according to the operation status of each software item, the button displays differently. a) Tap Update to update the selected item. b) Tap Pause to suspend the updating procedure. c) Tap Continue to go on updating the suspended update. To update the diagnostic software and TPMS service software 1. Make sure the Display Tablet is connected to a power source with stable access to the internet. 2.
Chapter 11 VCI Manager Operations This application allows you to pair up the Display Tablet with the VCI device, check the communication status, and update the VCI software and TPMS service firmware. Figure 11-1 Sample VCI Manager Screen 1. 2. Connection Mode – there are three connection modes available for selection. The connection state is displayed alongside. BT Paring – when paired to a wireless device, the connection state displays as Paired; otherwise it displays as Unpaired.
VCI Manager Operations BT Pairing during the synchronization procedure. Make sure the Display Tablet has sufficient battery level or is connected to an AC/DC power supply. To pair the VCI device with the Display Tablet 1. Power on the Display Tablet. 2. Insert the 16-pin vehicle data connector of the MaxiVCI V100 to the vehicle data link connector (DLC). 3. Tap the VCI Manager application on the MaxiSys Job Menu of the Display Tablet. 4. Select BT from the connection mode list. 5.
VCI Manager Operations TPMS Module Update To update the VCI device software 1. Power on the Display Tablet. 2. Connect the VCI device to Display Tablet via USB. 3. Tap the VCI Manager application on the MaxiSys Job Menu of the Display Tablet. 4. Select Update from the connection mode list. 5. The current version and the latest version of the VCI software will be displayed after a few seconds, click Update Now to update the VCI software if available. 11.
Chapter 12 Support Operations This application launches the Support platform which synchronizes Autel’s on-line service base station with the Display Tablet. In order to synchronize the device to your on-line account, you need to register the product through the Internet when you use it for the first time.
Support Operations Support Screen Layout 12.2 Support Screen Layout The Support application interface is navigated by 4 simple buttons on the top navigation bar, operation of each is described below in turn from left to right: Home Button – returns to the MaxiSys Job Menu. Back – returns to the previous screen, each press takes you back one step. Forward – each press moves forward one screen until you’ve reached the last screen visited. Refresh – reload and update the screen.
Support Operations My Account 12.3 My Account The My Account screen displays the comprehensive information of the user and the product, which is synchronized with the on-line registered account, including User Info, Device Info, Update Info and Service Info. Personal Info The User Info and Device Info are both included under the Personal Info section.
Support Operations User Complaint Screen Layout Figure 12-2 Sample Complaint Screen The User Complaint screen consists of two parts. 1. 2. Option Bar Period Filter – displays only the complaint records within the defined period on the list Status Filter – displays the corresponding complaint records according to the selected case status New Complaint Button – starts a new complaint case.
Support Operations User Complaint Waiting Customer Reply – indicates the complaint has been replied by the service personnel, and requires feedback from the customer Closed – indicates the complaint case has been processed, solved, and ended To view the detailed complaint session, tap the ○ > button on the right side of the case item. To establish a new complaint session 1. Register the product online. 2. Tap the Support application on the MaxiSys Job Menu.
Support Operations Data Logging 3. Tap Complaint on the Main Menu. 4. Select an existing complaint case item on the record list by tapping the ○ > button on its right side. The screen displays the complaint session details. 5. Tap the Post Reply button on the upper right side after viewing, to make a reply. An edit screen displays. 6. Input the content in the input field, and if necessary, upload an attaching file. 7. Tap Submit to post the reply. 8.
Support Operations Communities To make a reply in a Data Logging session 1. Tap on the Sent tag to view a list of submitted data loggings. 2. Select a specific item to view the latest update of the processing progress. 3. Tap on the input field at the bottom of the screen, and enter the texts. Or tap the Audio button to record a voice message, or camera button to take a picture. 4. Tap Send to deliver your message to the technical center. 12.
Support Operations Communities 2. Select a desired group according to the subject you are about to discuss. For example, if you are going to ask a question about the MaxiSys tablet, tap MaxiSys to start a discussion. 3. Enter your topic and the discussion content in the appropriate input field. 4. Select a category or edit tags for the discussed post. This will help other members with similar interest to find your post. 5. Tap OK to submit the post. To join and reply to a discussion post 1.
Support Operations Training Channels Figure 12-5 Sample User Profile Screen Profile – displays the user’s personal information and member status. The Related links allow you to check the Top Users (ranked according to their points and levels) in the communities, as well as to find out other online users. Avatar – allows you to select an image to set as your personal Avatar to be displayed in the communities. Stuff – displays all the discussions you’ve posted at various forums in a list. 12.
Support Operations FAQ Database 12.8 FAQ Database The FAQ section provides you comprehensive and abundant references for all kinds of questions frequently asked and answered about the use of Autel’s online member account, and shopping and payment procedures. Account – displays questions and answers about the use of Autel’s online user account. Shopping & Payment – displays questions and answers about online product purchase and payment methods or procedures.
Chapter 13 Training Operations The Training application provides and allows you to play various tutorial videos stored on the device. The stored training materials mainly consists of product usage tutorials and vehicle diagnostic training videos, all produced by top-notch technicians and product experts. The application also allows you to download or watch more associated videos online, by providing quick links to Autel’s online video database. Figure 13-1 Sample Training Application Screen 1.
Training Operations Operations 2. Select a video file from the main section. 3. Select a Player from the popup window if necessary. Now you can watch the video, it is played in full screen mode.
Chapter 14 Remote Desk Operations The Remote Desk application launches the TeamViewer Quick Support program, which is a simple, fast and secure remote control interface. You can use the application to receive ad-hoc remote support from Autel’s support center, colleagues, or friends, by allowing them to control your MaxiSys tablet on their PC via the TeamViewer software. 14.
Remote Desk Operations Operations To receive remote support from a partner 1. Power on the Display Tablet. 2. Tap the Remote Desk application on the MaxiSys Job Menu. The TeamViewer interface displays and the device ID is generated and shown. 3. Your partner must install the Remote Control software to his/her computer by downloading the TeamViewer full version program online (http://www.teamviewer.
Chapter 15 Quick Link Operations The Quick Link application provides you with convenient access to Autel’s official website and many other well-known sites in automotive service, which offers you abundant information and resources, such as technical help, knowledge base, forums, training, and expertise consultations, etc. Figure 15-1 Sample Quick Link Screen To open a quick link 1. Tap the Quick Link application on the MaxiSys Job Menu. The Quick Link application screen displays. 2.
Chapter 16 Oscilloscope Operations The Oscilloscope application configures the MaxiSys Diagnostic Device to operate as an automotive oscilloscope when work in combination with the MaxiScope module. This function provides all the features needed for performing electrical and electronic circuit tests as well as monitoring signal activities on any modern vehicles, which shows you what is really going on with a vehicle’s electrical system. 16.
Oscilloscope Operations Safety Information WARNING: C. Applying a voltage to the ground input is likely to cause permanent damage to the oscilloscope, the attached computer, and other equipment. To prevent measurement errors caused by poor grounding, always use the high-quality USB cable supplied with the oscilloscope. External connections DANGER: D. To prevent injury or death, use only the power cord and adaptor supplied with the product.
Oscilloscope Operations Glossary 16.2 Glossary AC/DC Control Each channel can be set to either AC coupling or DC coupling. With DC coupling, the voltage displayed onscreen is equal to the true voltage of the signal with respect to ground. With AC coupling, any DC component of the signal is filtered out, leaving only the variations in the signal for the AC component.
Oscilloscope Operations Glossary Time Base The time base controls the time interval across the scope display. Voltage Range The voltage range is the range between the maximum and minimum voltages that can be accurately captured by the oscilloscope. Sinusoidal Waveform This term describes the waveform characteristics typically found in circuits with large inductance and capacitance, and often referred to as an AC signal.
Oscilloscope Operations MaxiScope Module Figure 16-2 Sample Square Waveform Peak to peak voltage This term indicates the difference in voltage between the minimum and maximum voltages occurring in the waveform. 16.3 MaxiScope Module The MaxiScope Automotive Oscilloscope tool kit is optional and available for purchase along with the MaxiSys package. There are 2 versions (basic and advanced versions) available.
Oscilloscope Operations MaxiScope Module Figure 16-3 Front, Rear, and Top View 1. USB Port Connector 2. Input Channel A/B/C/D 3. LED Indicator Light – lights up when powered on, blinks when communicating, and shimmers when error occurs 4. Warning Triangle – indicates potential safety hazard that exists on the indicated connections, and appropriate precautions should be taken. Make sure you read through the Safety Information on page 114 before using. 5.
Oscilloscope Operations MaxiScope Module Technical Specifications Main Features Description Vertical resolution 12 bits Channels 4 Bandwidth 20MHz Accuracy Voltage: 1%; Time: 50ppm Sensitivity 10mV/div to 20V/div Input Ranges (full scale) ±50mV to ±100V in 11 ranges Input Impedance 1MΩ in parallel with 22pF Input Type Single-ended, BNC connector Input Coupling Software selectable AC/DC Overload Protection ±200V on single input Maximum Sampling (Single Shot) 1 or 2 channels in use 3 o
Oscilloscope Operations Screen Layout and Operations General PC Interface Description USB 2.0 – cable supplied Power Requirements Powered from USB port Compliance FCC (EMC), CE (EMC and LVD), RoHS Warranty 1 year NOTE*: Reduced to 20MS/s if channels A and B, or C and D, are enabled. 16.4 Screen Layout and Operations The Oscilloscope application works as a signal processing program that displays the shape of electrical signals onscreen with a live graph showing voltage against time.
Oscilloscope Operations Screen Layout and Operations 1. Top Toolbar – used for configurations of various settings and operations of the scope 2. Functional Buttons on the top – used for configurations of channel activation, measurement scale and trigger settings 3. Measurement Grid - displays measurements of voltage against time 4. Functional Buttons at the bottom – used for configurations of trigger, time base, and measurement parameter display settings. 16.4.
Oscilloscope Operations Button Name Save Help Scope Icon Screen Layout and Operations Description Tapping this button opens a submenu, on which displays 5 options allowing you to save, record and plays back the waveform data. Tap Save current page to take a screenshot image. Tap Record data to save the current waveform data. Tap Save Ref to save a copy of an existing signal waveform as reference. Tap Review data allows selecting and reviewing the previously stored waveform recordings.
Oscilloscope Operations Screen Layout and Operations Probe A probe is any transducer, measuring device or other accessory that you connect to an input channel of your MaxiScope module. Reference Waveform A Reference Waveform is a copy of an existing signal waveform saved as a reference. It can be retrieved to display as a comparative reference to examine a live signal. Up to 4 reference waveforms can be saved. Figure 16-5 Ref. Waveform Save Window To create a Reference Waveform: 1.
Oscilloscope Operations Screen Layout and Operations Figure 16-6 Recall Reference Waveform Window 16.4.
Oscilloscope Operations Screen Layout and Operations 16.4.3 Measurement Grid The 2 control features - Voltage per division and Time per division – enable the users to adjust the scope settings to suit the particular test measurement.
Oscilloscope Operations Screen Layout and Operations line up and down to move and view different areas of the scale. 4. Tap once on the screen area outside of the Y-axis to finish the voltage scale adjustment. To adjust the time base scale 1. Unselect the Y-axis if it’s activated. 2. Use your 2 fingers to adjust the time base with the typical zoom gestures on the measurement grid area. 16.4.
Oscilloscope Operations Screen Layout and Operations Figure 16-8 Measurement Rulers Display 16.4.5 Functional Buttons This group of buttons includes trigger setting buttons allowing you to set trigger source and trigger mode, a Time base button for adjustment, and a Measurement button with options for various measurement types. Trigger On/Off – taps to turn on/off the trigger. The button displays as Trigger Off when it is activated, and vice versa.
Oscilloscope Operations B. Troubleshooting Auto Mode - configures the trigger to occur every time when the scope captures the signal waveforms by the preset trigger point. The scope continues to draw the waveforms even when the signal is not in the trigger point range. Main Time Base – allows users to select an appropriate time per division. The time per division (10 divisions) is displayed along the bottom of the screen. The time base adjustment affects all of the active scope channels at once.
Oscilloscope Operations MaxiScope Firmware Update IMPORTANT: All vehicle communications must be terminated before resetting the USB connection to avoid damage to the devices and the vehicle. The Internet connection may be aborted during USB reset. If the communication between the MaxiScope and the Display Tablet still fails after USB reset, restart the Display Tablet and reconnect the MaxiScope. 16.
Chapter 17 Digital Inspection Operations The Digital Inspection application configures the Display Tablet to operate as a digital video scope by simply connecting the tablet to a Digital Inspection Camera. This function allows you to examine difficult-to-reach areas normally hidden from sight, with the ability to record digital still images and videos, which offers you an economical solution to inspect machinery, facilities, and infrastructure in a safe and quick way.
Digital Inspection Operations Additional Accessories 17.1 Additional Accessories The Digital Inspection Camera and its fittings are the additional accessories. Both sizes (8.5 mm and 5.5 mm) of the imager head are optional and available for purchase along with the standard MaxiSys tool kit. Digital Inspection Camera Figure 17-1 Digital Inspection Camera 1. Removable Imager Head Cable – connects to the tool when performing digital inspections for image and video viewing 2.
Digital Inspection Operations Additional Accessories Imager Head Accessories Figure 17-2 8.5mm Imager Head Accessories 1. Magnet – picks up small metal objects, such as dropped rings or screws 2. Hook – unclogs obstacles and picks up wires in the pipes or confined areas 3. Mirror – helps to look around corners and see the unreachable areas Figure 17-3 5.5mm Imager Head Accessories 1. Mirror – helps to look around corners and see the unreachable areas 2.
Digital Inspection Operations Additional Accessories 1. Hold the accessory and the imager head. 2. Slip the end of the accessory over the imager head and then fix the accessory. For 5.5mm Imager Head The two accessories, including the Magnet and Mirror (Figure 17-3), can be attached to the Imager Head with the same manner described below: 1. Hold the accessory and the imager head.
Digital Inspection Operations 2. Operations Screw the thread part of the accessory over the imager head to fix the accessory. 17.1.1 Technical Specifications Item Optimal Viewing Distance Description 1" to 14" (2.54cm to 35.56cm) with 8.5mm diameter imager head 3/8" to 12" (0.95cm to 30cm) with 5.
Digital Inspection Operations Operations To take pictures using the Digital Inspection application 1. Connect the Imager Head Cable to the USB port on the top side of the Display Tablet. 2. If not already done, power up the Display Tablet. 3. Tap the Digital Inspection application on the MaxiSys Job Menu. The Digital Inspection application interface displays, showing a camera operating screen. The default camera is now the Imager head. 4.
Digital Inspection Operations Operations 6. Tap the red ring on the operating screen to start recording. 7. Tap the red circle again to stop recording. The recorded video is automatically saved to the system Gallery. 8. Tap the thumbnail image on the top right corner to review the recorded video. 9. Tap the Play button to play the video. 10. Tap on the selected video and the edit toolbar instantly displays. 11. Tap the appropriate button to share, delete, or edit the video. 12.
Chapter 18 Maintenance and Service To ensure that the MaxiSys diagnostic tablet and the combined VCI unit perform at their optimum level, we advise that the product maintenance instructions covered in this section is read and followed. 18.1 Maintenance Instructions The following shows how to maintain your devices, together with precautions to take. Use a soft cloth and alcohol or a mild window cleaner to clean the touch screen of the tablet.
Maintenance and Service Troubleshooting Checklist 18.2 Troubleshooting Checklist A. B. When the Display Tablet does not work properly: Make sure the tablet has been registered online. Make sure the system software and diagnostic application software are properly updated. Make sure the tablet is connected to the Internet. Check all cables, connections, and indicators to see if the signal is being received. When battery life is shorter than usual: C.
Maintenance and Service About Battery Usage Do not use a damaged battery charger. Do not disassemble or open crush, bend or deform, puncture or shred. Do not modify or remanufacture, attempt to insert foreign objects into the battery, expose to fire, explosion or other hazard. Make sure to use the charger and USB cables only that come together in the package. If you use the other charger and USB cables, you might incur malfunction or failure of the device.
Maintenance and Service Service Procedures Call 1-855-288-3587/1-855-AUTELUS 0086-755-86147779 (China). Contact the local distributer or agent. Visit our website http://pro.autel.com or www.autel.com. (North America), or Repair Service If it becomes necessary to return your device for repair, please download the repair service form from www.autel.com, and fill in the form.
Chapter 19 Compliance Information FCC Compliance FCC ID: WQ8MAXISYSMS906TS (for MaxiSys MS906TS) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Compliance Information Important Information the device transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the device is designed to operate at multiple power levels so as to use only the power required to reach the network.
Chapter 20 Warranty 12-Month Limited Warranty Autel Intelligent Technology Corp., Ltd.