8 Mode 6
Mode 6 refers to the advanced test results for On-Board Diagnostic System
Monitors. Example monitors include Oxygen Sensors and Misfire Counters.
Mode 6 will tell you if the monitors are passing their tests and if the values
are within acceptable range. For each test, the result displays six
parameters, MID, TID, Module ID, Value, Min, and Max. MID (Monitor ID)
represents what is being tested. TID (Test ID) represents what specific test
is being running. Min is the minimal allowable test result that will not set a
DTC. Value is the actual result of the test. Max is the maximum allowable
test result that will not set a DTC.
Figure 8-1 Sample Mode 6 Screen