User's Manual

6
2) OBDII Connector
The OBDII connector connects the device to the vehicles DLC via a
standard high density DB-26 MVCI OBDII cable.
3) External Programming Voltage Output
The external programming socket provides the user with access to
the 5-20V programming voltage. This is used for Mitsubishi, Subaru
or any other vehicle that needs voltage on an additional connector.
4) A/D Inputs
The 12-bit analog inputs are setup for an input range of 0 - 27.5VDC
and are electrically protected against reverse voltage and over
voltage conditions. The Mating connector is a High Density DB-15.
NOTE: The 3) External Programming Voltage Output and 4)
A/D Input ports are currently used for internal debugging only.
TABLE 2 GENERAL PURPOSE ANALOG INPUTS
Pin
Function
Direction
2
Channel 6
In
4
Channel 3
In
6
Battery Voltage
Out (200mA max)
8
Channel 4
In
10
Channel 1
In
12
Channel 5
In
14
Channel 2
In
1,3,5,7,9,
11,13,15
Ground