LIKTCNA0 Page 27
C.1 Programming functions
The dip switches 1 and 2 programme the same functions in 433 MHZ and in 870 MHZ modules.
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
1
8
2 7
3 6
5
4
ON
OFF
Group of 8
dip switches
in the
transmitting
module
E16STXEU_
* passive emergency: the receiving unit decides autonomously to switch the system off when
the radio signal is incorrect, interrupted or there is interference
** Following from the status of dip switch no.1 or possibly due to a failure (of the dip
switch itself), a delay up to max 1 second may occasionally occur between command
release and actual deactivation of outputs. This is due to the characteristics of radio
propagation (i.e.: EM interferences, near out-of-range condition). Care must be taken to
ensure that this could never lead to.
Group of 8
dip switches
in the
receiving
module
E16SRXEU_
DIP SWITCH Functional description
Dip switch 1 OFF enables the automatic off switch: if the
transmitting unit is on but none of the commands is operational,
after about 3,5 minutes the unit switches itself off automatically.
Dip switch 1 ON disables the automatic switch off function: if the
transmitting unit is on but no commands are activated for about 3,5
minutes, automatic switch off does not occur.
Dip switch 2 OFF activates the insufficient power acoustic signal.
When the power supply to the transmitting unit goes below a
certain value, the relay in the receiving unit is activated.
Dip switch 2 ON switches off the insufficient power acoustic
signal.
DIP SWITCH Functional Description
Dip switch 1 in the ON position fixes passive emergency* at 0.35
seconds. **
Dip switch 2 OFF activates the insufficient power acoustic signal.
When the power supply to the transmitting unit goes below a
certain value, the relay in the receiving unit is activated.
Dip switch 2 ON switches off the insufficient power acoustic
signal.
Dip switch 1 in the ON position fixes passive emergency* at 1
second.
1 2
3
4
ON
OFF
1 2
3
4
ON
OFF
Group of 4
dip switches
in the
transmitting
module
E16STXEU_
Group of 4
dip switches
in the
receiving
module
E16SRXEU_
DIP SWITCH
DIP SWITCH