5 Technical Data
General
Number of avaible commands
Transmitting unit
Receiving unit
Power supply
Antenna
Max switching capacity of STOP contacts
Max switching capacity of SAFETY contacts
Max switching capacity of command contacts
Additional command unit
Max switching capacity of SAFETY contacts
Max switching capacity of command contacts
Frequency range
Programmable radio channel
Hamming distance
Probability of non-recognition of error
Typical working range
Working temperature
Time of reply to commands
Time of reply to STOP
Passive emergency time
Power supply
Antenna
Output power
Time of switching off warning (caused by insufficient power supply)
Housing
Minimum protection grade
Weight
Housing
Minimum protection grade
Weight
Housing
Minimum protection grade
Weight
160 mm
75 mm
110 mm
72 mm
75 mm
110 mm
902 - 928 MHz
32
< 10 exp-11
100 m
-4°F - +158°F
< 100 ms
< 100 ms
1 second; (opt 0,35 second)
14+start+stop (+6 opt)
9 - 30 Vac/dc (3W)
external with 2,5 metres long cable
meets FCC Part 15 for license-free operation
ca 3,5 min
NORIL ®
IP20
400 g
10 - 30 Vac/dc (7W)
external with 2,5 metres long cable
4A T (250 Vac)
4A T (250 Vac)
4A T (250 Vac)
NORIL ®
IP20
500 g
4A T (250 Vac)
4A T (250 Vac)
NORIL ®
IP20
200 g
³ 8
Additional command unit
dimensions
Transmitting/receiving unit
dimensions