User's Manual
Page 14 of 16 8 - Programming LIMJNMA0
English
8 PROGRAMMING
The dip switches must be programmed with the battery removed
from the transmitting unit and can be done only by authorised per-
sonnel.
The incorrect closure of the transmitting unit can compromise seal
between the casings and thereby the protection grade from dust and
water.
DIP SWITCHES ON E16STXUS1 RADIO TRANSMITTING MODULE
The group of eight dip switches
found in the module is necessary
for programming some opera-
tions and setting the operating
frequency.
The programming set in the oth-
er group of four dip switches
must never be modified.
Group of 8 dip switches
DIP POS. DESCRIPTION
1
ON The transmitting unit never switches off automatically
OFF
The transmitting unit switched on without movement com-
mands entered switches off after approx. 3,5 minutes
2
ON Deactivated of low battery warning from horn on machine.
OFF Activation of low battery warning from horn on machine
3
ON
With DIP 8 OFF, automatic scan of the frequencies in the
902 - 928 MHz
OFF
With DIP 8 OFF, automatic scan of the frequencies in the
902 - 928 MHz
3-7 ON/OFF With DIP 8 ON see "Appendix: Frequency Table"
8
ON
Manual selection of frequencies
(DIP 3 - DIP 7 see "Appendix: Frequency Table")
OFF
Automatic scan mode of frequencies in the band selected with
DIP 3 (DIP 4 - DIP 7 not relevant)
!
Group of 8
dip switches
Group of 4 dip
switches
These eight dip switches must be programmed in the same manner
as the group of 8 dip switches (excluding DIP 1) present in the radio
module of the receiving unit (see manual).
!