Light signals
AUTEC - Air series
Signal Meaning
The green [B] and red [A] LEDs are
steady on during start up.
A wrong "ID internal tx memory" has been inserted in the
Transmitting Unit, or this is a "BACK-UP UNIT".
The green [B] and red [A] LEDs
blink 3 times per second during
start up.
"ID internal tx memory" is damaged.
The green LED [B] is lit with a
steady light and the red LED [A]
blinks two times per second during
start up.
The START actuator is activated.
The green [B] and red [A] LEDs
blink alternating.
30 s left before the Transmitting Unit automatically
switches o.
The green LED [B] repeats the
sequence: 3 blinks and a pause,
and the red LED [A] is steady on
during start up.
The procedure corresponding to the UNPAIR submenu
has been carried out.
7.2 Green CHARGE LED [D] and red CHARGE LED [E]
The meaning of green CHARGE LED [D] and red CHARGE LED [E] illumination is described
in the following table. They only illuminate when the Transmitting Unit is being recharged.
The meaning of the red and green CHARGE LED signals cannot be modied.
Signal Meaning
The green CHARGE LED [D] is
steady on.
The Transmitting Unit is under charge and charging has
been completed.
The red CHARGE LED [E] is steady
on.
The Transmitting Unit is under charge and charging has
not been completed yet.