Instruction Manual
LIURPD002_eng-00 AUTEC
18
9.3 Positioning the antenna
The Receiving Unit is not set up for the use of an antenna extension kit.
9.4 Wiring
The metal housing of the plug connecting the Receiving Unit to the Machine's
electrical panel mu be wired to the earth connector so as to avoid hazards
relating to electrical safety.
Voltage in the outputs of the Receiving Unit shall not exceed 250V .
In the Receiving Unit, the STOP circuit is made with two contacts connected
in series and it provides a common to all commands (except for the commands
corresponding to relay K7, if present).
Pay special attention to currents and voltages flowing in the STOP circuit
output: they shall not exceed the maximum permitted values (see chapter 4).
In the Receiving Unit, the SAFETY relay is always connected in series to the
common of the movement commands: therefore the re position of actuators
is always protected from unintended movements.
These connections cannot be modified.
To power the HACRP8 (Type FA00M) or the HACRP8-A (Type FAA0M) Receiving
Unit with 400V , connect it to a 230/400V three-phase electrical line (230V
line to neutral; 400V line to line voltage).