User's Manual

The STOP circuit in the receiving unit has two contacts connected in series
through a wire jumper (manufacturer's standard wiring). If the machine needs
a STOP circuit with two separate contacts (four wires), this bridge can be
removed. In this case, the installer is responsible for wiring in a way that
assures the required safety level.
Group the wiring away from the electronic module, in order to avoid
interferences and hazards related to electrical safety.
Evaluate the radio remote control's wiring and remember that if the output
dedicated to the machine's horn, siren or blinker is used for another command
due to application's and/or functional reasons, some procedures in the
“Con󰄈gurationMenu”mayresultunavailablelateron.
To wire the terminals corresponding to the commands' outputs, to the STOP
outputs and to the SAFETY outputs, it is recommended to use a slot screwdriver
with a tip size of 3.5x0.4mm.
3.5 At end of installation
Make sure that during installation the safety mechanisms on the radio remote
controland/orinthemachinehavenotbeenmadeine󰓐ectivebypossible
procedures carried out.
AUTEC - Air series
Warnings for installation 13
LIAIRE01-00